Literature DB >> 18324451

Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup.

Philip M Faris1, E Michael Keating, Alex Farris, John B Meding, Merrill A Ritter.   

Abstract

A retrospective study of 201 anatomic graduated component total knee arthroplasties implanted with hybrid fixation at the authors' center was performed in response to conflicting data in the literature concerning the benefits of a hybrid method. Selection for hybrid fixation was nonrandomized and based on femoral component fit. Survivorship analysis was performed, and rates of radiolucent lines surrounding the femoral component and occurrence of osteolysis were noted. At 7 and 13 years, survivorship with tibial or femoral revision as the end point was 0.9926 and 0.9732, respectively. Radiolucencies were found adjacent to 15 femoral components at final followup (seven in Zone 1, three in Zone 2, five in Zone 3, one in Zone 4, two in Zone 5, zero in Zone 6). Osteolysis was observed in one knee after secondary evaluation. Hybrid fixation in a selected patient population can result in excellent results in middle to long-term followup.

Entities:  

Mesh:

Year:  2008        PMID: 18324451      PMCID: PMC2311479          DOI: 10.1007/s11999-008-0195-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  57 in total

1.  Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris.

Authors:  S K Puloski; R W McCalden; S J MacDonald; C H Rorabeck; R B Bourne
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

2.  Long-term followup of anatomic graduated components posterior cruciate-retaining total knee replacement.

Authors:  M A Ritter; M E Berend; J B Meding; E M Keating; P M Faris; B M Crites
Journal:  Clin Orthop Relat Res       Date:  2001-07       Impact factor: 4.176

3.  Tibial interface wear in retrieved total knee components and correlations with modular insert motion.

Authors:  Anand R Rao; Gerard A Engh; Matthew B Collier; Smain Lounici
Journal:  J Bone Joint Surg Am       Date:  2002-10       Impact factor: 5.284

4.  Osteolysis in failed total knee arthroplasty: a comparison of mobile-bearing and fixed-bearing knees.

Authors:  Chun-Hsiung Huang; Hon-Ming Ma; Jiann-Jong Liau; Fang-Yuan Ho; Cheng-Kung Cheng
Journal:  J Bone Joint Surg Am       Date:  2002-12       Impact factor: 5.284

5.  The effect of the preoperative bone quality on the fixation of the tibial component in total knee arthroplasty.

Authors:  M G Li; K G Nilsson
Journal:  J Arthroplasty       Date:  2000-09       Impact factor: 4.757

6.  Knee prostheses--one step forward, two steps back.

Authors:  J Goodfellow
Journal:  J Bone Joint Surg Br       Date:  1992-01

7.  Metal-backed and all-polyethylene tibial components in total knee replacement.

Authors:  J A Rodriguez; N Baez; V Rasquinha; C S Ranawat
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

8.  Cementless porous-coated total knee arthroplasty: 10-year results in a consecutive series.

Authors:  H M Schrøder; A Berthelsen; G Hassani; E B Hansen; S Solgaard
Journal:  J Arthroplasty       Date:  2001-08       Impact factor: 4.757

9.  Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design : five to eight-year follow-up.

Authors:  Michael R O'Rourke; John J Callaghan; Devon D Goetz; Patrick M Sullivan; Richard C Johnston
Journal:  J Bone Joint Surg Am       Date:  2002-08       Impact factor: 5.284

10.  Early failures among 7,174 primary total knee replacements: a follow-up study from the Norwegian Arthroplasty Register 1994-2000.

Authors:  Ove Furnes; Birgitte Espehaug; Stein Atle Lie; Stein Emil Vollset; Lars Birger Engesaeter; Leif Ivar Havelin
Journal:  Acta Orthop Scand       Date:  2002-04
View more
  13 in total

1.  Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.

Authors:  Shinichi Kuriyama; Katsufumi Hyakuna; Satoshi Inoue; Yasutsugu Kawai; Yasuyuki Tamaki; Hiromu Ito; Shuichi Matsuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-02-14       Impact factor: 4.342

2.  Cruciate-retaining TKA using a third-generation system with a four-pegged tibial component: a minimum 10-year followup note.

Authors:  Adam J Schwartz; Craig J Della Valle; Aaron G Rosenberg; Joshua J Jacobs; Richard A Berger; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2010-05-04       Impact factor: 4.176

3.  The Rotaglide mobile-bearing total knee arthroplasty: no difference between cemented and hybrid implantation.

Authors:  Michael Iosifidis; Efthymios Iliopoulos; Dimos Neofytou; Nikolaos Sakorafas; Dimitrios Andreou; Dimitrios Alvanos; Anastasios Kyriakidis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-12       Impact factor: 4.342

Review 4.  Validity of published outcome data concerning Anatomic Graduated Component total knee arthroplasty: a structured literature review including arthroplasty register data.

Authors:  Reinhard Schuh; Gerald Dorninger; Mark Agreiter; Nikolaus Boehler; Gerold Labek
Journal:  Int Orthop       Date:  2011-04-13       Impact factor: 3.075

5.  Osteolysis in well-functioning fixed- and mobile-bearing TKAs in younger patients.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2010-04-01       Impact factor: 4.176

6.  Asian-specific total knee system: 5-14 year follow-up study.

Authors:  Kunihiro Hosaka; Shu Saito; Takao Ishii; Sei Mori; Takanobu Sumino; Yasuaki Tokuhashi
Journal:  BMC Musculoskelet Disord       Date:  2011-11-02       Impact factor: 2.362

7.  Long-term Results of Hybrid Total Knee Arthroplasty: Minimum 10-years Follow-up.

Authors:  Young Joon Choi; Ki Won Lee; Chung Hwan Kim; Hyung Sun Ahn; Jae Kwang Hwang; Jeong Ho Kang; Hee Don Han; Wan Jong Cho; Jun Seok Park
Journal:  Knee Surg Relat Res       Date:  2012-05-31

8.  The use of a modular titanium baseplate with a press-fit keel implanted with a surface cementing technique for primary total knee arthroplasty.

Authors:  Christopher E Pelt; Jill Erickson; Bryt A Christensen; Benjamin Widmer; Erik P Severson; David Evans; Christopher L Peters
Journal:  Biomed Res Int       Date:  2014-05-14       Impact factor: 3.411

9.  The role of the posterior cruciate ligament in total knee replacement.

Authors:  M A Ritter; K E Davis; J B Meding; A Farris
Journal:  Bone Joint Res       Date:  2012-04-01       Impact factor: 5.853

10.  Hybrid total knee arthroplasty revisited: midterm followup of hybrid versus cemented fixation in total knee arthroplasty.

Authors:  Christopher E Pelt; Jeremy M Gililland; Justin Doble; Benjamin M Stronach; Christopher L Peters
Journal:  Biomed Res Int       Date:  2013-09-25       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.