Literature DB >> 7699597

Comparative study of antirotational single tooth abutments.

A Balfour1, G R O'Brien.   

Abstract

Identifying the functional and mechanical limitations of single tooth implant systems is essential for the long-term success of the restoration. Three designs with different prosthetic connections were evaluated with their corresponding single tooth abutments for structural integrity and cyclic fatigue. The internal implant octagon was the weakest connection under off-axis impact loading and lateral loading, and the external hexagon implant was rendered unrestorable under lateral loading. Overall, the internal hexagon design was found to provide the highest degree of single tooth stability. This was attributed to the increased material strength of the titanium alloy implant in comparison to the softer CP titanium implant, and to the abutment's longer, 1-degree tapered mating hexagon.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7699597     DOI: 10.1016/s0022-3913(05)80270-7

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

1.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

2.  A three-dimensional finite element analysis of a passive and friction fit implant abutment interface and the influence of occlusal table dimension on the stress distribution pattern on the implant and surrounding bone.

Authors:  Hasan Sarfaraz; Anoopa Paulose; K Kamalakanth Shenoy; Akhter Hussain
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

3.  The fracture strength by a torsion test at the implant-abutment interface.

Authors:  Fumihiko Watanabe; Kazuhiko Hiroyasu; Kazuhiko Ueda
Journal:  Int J Implant Dent       Date:  2015-10-10

4.  In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening.

Authors:  Onur Dincer Kose; Burcin Karataslı; Sabit Demircan; Taha Emre Kose; Erhan Cene; Serhan Aydın Aya; Mehmet Ali Erdem; Abdulkadir Burak Cankaya
Journal:  Biomed Res Int       Date:  2017-04-03       Impact factor: 3.411

5.  Deformation of the Internal Connection of Narrow Implants after Insertion in Dense Bone: An in Vitro Study.

Authors:  Rafael Delgado-Ruiz; Ana Nicolas Silvente; Georgios Romanos
Journal:  Materials (Basel)       Date:  2019-06-06       Impact factor: 3.623

6.  Evaluation of reverse torque values and failure loads of three different abutment designs with internal connections.

Authors:  Saied Nokar; Habib Hajimiragha; Leyla Sadighpour; Azam Sadat Mostafavi
Journal:  Dent Res J (Isfahan)       Date:  2020-12-10

7.  Influence of the implant abutment types and the dynamic loading on initial screw loosening.

Authors:  Eun-Sook Kim; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

Review 8.  Technical complications of implant-causes and management: A comprehensive review.

Authors:  Swati Gupta; Hemant Gupta; Amrit Tandan
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.