Literature DB >> 7673265

Errors in alignment of center of pressure and foot coordinates affect predicted lower extremity torques.

S T McCaw1, P DeVita.   

Abstract

The purpose of the study was to quantify the effect of errors in spatial alignment between the center of pressure recorded from a force platform and the coordinates of the foot recorded from film on resultant joint torques in the lower extremity during the stance phase of gait. Two-dimensional kinematic and kinetic data from eight subjects performing walking and running were analyzed using inverse dynamics with the obtained center of pressure values and with +/- 0.5 and +/- 1.0 cm shifts in the anteroposterior location of the center of pressure under the support foot. Shifting the center of pressure posteriorly increased the flexor (dorsiflexor) torques at the hip and ankle and decreased the extensor (plantarflexor) torques at these joints. This shift also caused an increase in the extensor and a decrease in the flexor torques at the knee. Shifting the center of pressure anteriorly caused the opposite effects at each joint. The +/- 0.5 and +/- 1.0 cm shifts in the location of the center of pressure caused, on average, 7 and 14% changes, respectively, in maximum joint torque and angular impulse values. Relative transition times between flexor and extensor torques were either increased or decreased, on average, by 7 and 13%, respectively for the two conditions over all trials. Based on these results, it is concluded that due to potential errors in the spatial alignment of kinetic and kinematic data, joint torques in the literature on gait should be considered as approximations of the true values.

Mesh:

Year:  1995        PMID: 7673265     DOI: 10.1016/0021-9290(94)00151-s

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  12 in total

1.  Instrumented staircase for ground reaction measurement.

Authors:  R Riener; M Rabuffetti; C Frigo; J Quintern; G Schmidt
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

2.  Joint-level kinetic redundancy is exploited to control limb-level forces during human hopping.

Authors:  Jasper T Yen; Arick G Auyang; Young-Hui Chang
Journal:  Exp Brain Res       Date:  2009-06-04       Impact factor: 1.972

3.  The relation between mild leg-length inequality and able-bodied gait asymmetry.

Authors:  Matthew K Seeley; Brian R Umberger; Jody L Clasey; Robert Shapiro
Journal:  J Sports Sci Med       Date:  2010-12-01       Impact factor: 2.988

4.  Dynamic assessment of center of pressure measurements from an instrumented AMTI treadmill with controlled precision.

Authors:  Emma Fortune; Jeremy Crenshaw; Vipul Lugade; Kenton R Kaufman
Journal:  Med Eng Phys       Date:  2017-02-01       Impact factor: 2.242

5.  Dynamic stability margin using a marker based system and Tekscan: a comparison of four gait conditions.

Authors:  Vipul Lugade; Kenton Kaufman
Journal:  Gait Posture       Date:  2013-12-27       Impact factor: 2.840

Review 6.  Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review.

Authors:  Valentina Camomilla; Andrea Cereatti; Andrea Giovanni Cutti; Silvia Fantozzi; Rita Stagni; Giuseppe Vannozzi
Journal:  Biomed Eng Online       Date:  2017-08-18       Impact factor: 2.819

7.  A simple method for calibrating force plates and force treadmills using an instrumented pole.

Authors:  Steven H Collins; Peter G Adamczyk; Daniel P Ferris; Arthur D Kuo
Journal:  Gait Posture       Date:  2008-08-27       Impact factor: 2.840

8.  Spot check of the calibrated force platform location.

Authors:  M Rabuffetti; M Ferrarin; F Benvenuti
Journal:  Med Biol Eng Comput       Date:  2001-11       Impact factor: 3.079

9.  Three-dimensional lower extremity joint loading in a carved ski and snowboard turn: a pilot study.

Authors:  Miriam Klous; Erich Müller; Hermann Schwameder
Journal:  Comput Math Methods Med       Date:  2014-09-15       Impact factor: 2.238

10.  A simple state-determined model reproduces entrainment and phase-locking of human walking.

Authors:  Jooeun Ahn; Neville Hogan
Journal:  PLoS One       Date:  2012-11-12       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.