Dynamic assessment of center of pressure measurements from an instrumented AMTI treadmill with controlled precision.

Emma Fortune1, Jeremy Crenshaw2, Vipul Lugade3, Kenton R Kaufman4.   

Abstract

With the increasing use of instrumented force treadmills in biomechanical research, it is imperative that the validity of center of pressure (COP) measurements is established. The study aims were to compare an instrumented treadmill's static-belt COP accuracy to that of a floor-embedded platform, develop a novel method to quantify dynamic-belt COP accuracy with controlled precision and perform an initial investigation of how dynamic COP accuracy changes with weight and velocity. Static COP accuracy was assessed by applying a force while moving a rigid rod in a circular clockwise motion at nine positions of interest on the two treadmill and two ground-embedded force plates. Dynamic COP accuracy was assessed for weights (68.0, 102.1, and 136.1kg), applied through a ball bearing of 2.54cm circumference, with peak treadmill belt speeds of 0.5, 0.75, and 1.0m/s. COP accuracy was assessed relative to motion capture marker trajectories. Statically, treadmill COP error was similar to that of the ground-embedded force plates and that reported for other treadmills. Dynamically, COP error appeared to vary systematically with weight and velocity and in the case of anteroposterior COP error, shear force, although testing with a larger number of weights and velocities is needed to fully define the relationship. This novel method can be used to assess any instrumented treadmill's dynamic COP accuracy with controlled precision.
Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy; Biomechanics; Force platforms; Kinetics; Validation

Mesh:

Year:  2017        PMID: 28161106      PMCID: PMC5352472          DOI: 10.1016/j.medengphy.2017.01.002

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  15 in total

1.  A treadmill-based system for measuring symmetry of gait.

Authors:  E R Draper
Journal:  Med Eng Phys       Date:  2000-04       Impact factor: 2.242

2.  A three-dimensional kinematic and kinetic comparison of overground and treadmill walking in healthy elderly subjects.

Authors:  Jaclyn R Watt; Jason R Franz; Keith Jackson; Jay Dicharry; Patrick O Riley; D Casey Kerrigan
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-03-29       Impact factor: 2.063

3.  A force measuring treadmill in clinical gait analysis.

Authors:  Frédéric Dierick; Massimo Penta; David Renaut; Christine Detrembleur
Journal:  Gait Posture       Date:  2004-12       Impact factor: 2.840

4.  Testing of a tri-instrumented-treadmill unit for kinetic analysis of locomotion tasks in static and dynamic loading conditions.

Authors:  Gabriele Paolini; Ugo Della Croce; Patrick O Riley; Frederic K Newton; D Casey Kerrigan
Journal:  Med Eng Phys       Date:  2006-06-06       Impact factor: 2.242

5.  A kinematics and kinetic comparison of overground and treadmill running.

Authors:  Patrick O Riley; Jay Dicharry; Jason Franz; Ugo Della Croce; Robert P Wilder; D Casey Kerrigan
Journal:  Med Sci Sports Exerc       Date:  2008-06       Impact factor: 5.411

6.  Gait analysis on split-belt force treadmills: validation of an instrument.

Authors:  Luigi Tesio; Viviana Rota
Journal:  Am J Phys Med Rehabil       Date:  2008-07       Impact factor: 2.159

7.  Errors in alignment of center of pressure and foot coordinates affect predicted lower extremity torques.

Authors:  S T McCaw; P DeVita
Journal:  J Biomech       Date:  1995-08       Impact factor: 2.712

8.  Force treadmill for measuring vertical and horizontal ground reaction forces.

Authors:  R Kram; T M Griffin; J M Donelan; Y H Chang
Journal:  J Appl Physiol (1985)       Date:  1998-08

9.  Use of an instrumented treadmill for real-time gait symmetry evaluation and feedback in normal and trans-tibial amputee subjects.

Authors:  J B Dingwell; B L Davis; D M Frazier
Journal:  Prosthet Orthot Int       Date:  1996-08       Impact factor: 1.895

10.  A simple method for calibrating force plates and force treadmills using an instrumented pole.

Authors:  Steven H Collins; Peter G Adamczyk; Daniel P Ferris; Arthur D Kuo
Journal:  Gait Posture       Date:  2008-08-27       Impact factor: 2.840

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.