Spot check of the calibrated force platform location.

M Rabuffetti1, M Ferrarin, F Benvenuti.   

Abstract

In a movement analysis laboratory, stereophotogrammetric motion capture systems and force platforms must share one absolute reference frame that allows the computation of joint moments and powers. The correct calibration of the platform location identifies the transformation between force plate and absolute reference systems, which determines the spatial coherence among the equipments' measurements. The aim of this study was to develop and test a spot check for the assessment of platform location calibration. Platform location calibration was assessed by comparing the measured outcome of an experiment performed with a pointed rigid rod bearing a set of markers with the corresponding expected results, computed with a model. A set of indices was then proposed to define a confidence volume in which the true ground reaction force is expected to be. The spot check was applied to a real laboratory setup and the effects of simulated platform mislocations were analysed. It was verified that the hip joint moment may be equally affected by a single marker misplacement of about 20mm during platform location calibration, an occurrence that was clearly identified by the spot check, and by a hip centre location inaccuracy of 30mm.

Entities:  

Mesh:

Year:  2001        PMID: 11804169     DOI: 10.1007/BF02345435

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   3.079


  16 in total

1.  Instrumented staircase for ground reaction measurement.

Authors:  R Riener; M Rabuffetti; C Frigo; J Quintern; G Schmidt
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

2.  Validation protocol of models for centre of mass estimation.

Authors:  M Rabuffetti; G Baroni
Journal:  J Biomech       Date:  1999-06       Impact factor: 2.712

3.  A simple and practical method for evaluating overall measurement error of joint moments obtained by a force plate and a position sensing device.

Authors:  S Miyazaki
Journal:  Front Med Biol Eng       Date:  1992

4.  Accuracy of determining the point of force application with piezoelectric force plates.

Authors:  M F Bobbert; H C Schamhardt
Journal:  J Biomech       Date:  1990       Impact factor: 2.712

5.  Functionally oriented and clinically feasible quantitative gait analysis method.

Authors:  C Frigo; M Rabuffetti; D C Kerrigan; L C Deming; A Pedotti
Journal:  Med Biol Eng Comput       Date:  1998-03       Impact factor: 2.602

6.  Static in situ calibration of force plates.

Authors:  M G Hall; H E Fleming; M J Dolan; S F Millbank; J P Paul
Journal:  J Biomech       Date:  1996-05       Impact factor: 2.712

7.  The effect of variation in knee center location estimates on net knee joint moments.

Authors: 
Journal:  Gait Posture       Date:  1998-01-01       Impact factor: 2.840

8.  Kinematic characteristics of standing disequilibrium: reliability and validity of a posturographic protocol.

Authors:  F Benvenuti; R Mecacci; I Gineprari; S Bandinelli; E Benvenuti; L Ferrucci; A Baroni; M Rabuffetti; M Hallett; J M Dambrosia; S J Stanhope
Journal:  Arch Phys Med Rehabil       Date:  1999-03       Impact factor: 3.966

9.  Ground reaction: intrinsic and extrinsic variability assessment and related method for artefact treatment.

Authors:  M Rabuffetti; C Frigo
Journal:  J Biomech       Date:  2001-03       Impact factor: 2.712

10.  A spot check for estimating stereophotogrammetric errors.

Authors:  U Della Croce; A Cappozzo
Journal:  Med Biol Eng Comput       Date:  2000-05       Impact factor: 3.079

View more
  1 in total

1.  A simple method for calibrating force plates and force treadmills using an instrumented pole.

Authors:  Steven H Collins; Peter G Adamczyk; Daniel P Ferris; Arthur D Kuo
Journal:  Gait Posture       Date:  2008-08-27       Impact factor: 2.840

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.