Impression technique for the assessment of oedema: comparison with a new tactile sensor that measures physical properties of tissue.

O A Lindahl1, S Omata.   

Abstract

To measure tissue oedema, the impression technique and a new tactile sensor technique are compared and evaluated in a silicone rubber model and in an in vivo rat testis model. The principles of the two techniques differ in that the impression technique evaluates interstitial fluid flow FT and peak force F(O) when tissue is compressed, whereas the tactile sensor evaluates the hardness/softness or change in resonance frequency delta f when a vibrating rod is attached to tissue. Both techniques can detect changes in silicone hardness/softness or in hormone-induced changes of testis interstitial fluid. Although both F(O) and FT are significantly correlated to delta f in the experiments, it is concluded that F(O) is the most promising impression parameter to give valuable information about the hardness of living tissue as compared with delta f. The comparison indicates that the impression technique is the most easy to interpret, non-invasive tool to assess tissue oedema so far developed.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7616777     DOI: 10.1007/BF02522941

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  7 in total

1.  Noninvasive method for the assessment of subcutaneous oedema.

Authors:  M Mridha; S Odman
Journal:  Med Biol Eng Comput       Date:  1986-07       Impact factor: 2.602

2.  Relationship between human chorionic gonadotrophin-induced changes in testicular microcirculation and the formation of testicular interstitial fluid.

Authors:  A Widmark; J E Damber; A Bergh
Journal:  J Endocrinol       Date:  1986-06       Impact factor: 4.286

3.  Voluminometric estimation of the degree of lymphedema and its therapy by pneumatic compression.

Authors:  I Swedborg
Journal:  Scand J Rehabil Med       Date:  1977

4.  Evaluation of the impression technique by measuring interstitial oedema in rat testis.

Authors:  O Lindahl; A Bergh; J E Damber; K A Angquist
Journal:  Acta Physiol Scand       Date:  1991-11

5.  Testicular microcirculation in the rat studied by videophotometric capillaroscopy, fluorescence microscopy and laser Doppler flowmetry.

Authors:  J E Damber; A Bergh; B Fagrell; O Lindahl; P Rooth
Journal:  Acta Physiol Scand       Date:  1986-03

6.  Fluid translocation measurement. A method to study pneumatic compression treatment of postmastectomy lymphoedema.

Authors:  M Mridha; S Odman
Journal:  Scand J Rehabil Med       Date:  1989

7.  Impression technique for the assessment of oedema. Technical improvement and methodological evaluation of a new technique.

Authors:  O Lindahl; K A Angquist; S Odman
Journal:  Med Biol Eng Comput       Date:  1991-11       Impact factor: 2.602

  7 in total
  6 in total

1.  A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model.

Authors:  A Eklund; A Bergh; O A Lindahl
Journal:  Med Biol Eng Comput       Date:  1999-09       Impact factor: 2.602

2.  Prostate tissue stiffness as measured with a resonance sensor system: a study on silicone and human prostate tissue in vitro.

Authors:  Ville Jalkanen; Britt M Andersson; Anders Bergh; Börje Ljungberg; Olof A Lindahl
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

3.  Quantitative analysis of muscle hardness in tetanic contractions induced by electrical stimulation in rats.

Authors:  Makoto Morisada; Kaoru Okada; Kenji Kawakita
Journal:  Eur J Appl Physiol       Date:  2006-06-13       Impact factor: 3.078

4.  Prostate cancer detection with an improved resonance sensor system: parameter evaluation in a silicone model and on human prostate tissue in vitro.

Authors:  Peter Lindberg; Britt Andersson; Anders Bergh; Börje Ljungberg; Olof Lindahl
Journal:  Med Biol Eng Comput       Date:  2006-11-09       Impact factor: 2.602

5.  Edema and elasticity of a fronto-temporal decompressive craniectomy.

Authors:  Daikei Takada; Hidemasa Nagai; Kouzo Moritake; Yasuhiko Akiyama
Journal:  Surg Neurol Int       Date:  2012-01-21

6.  Prostate Cancer Detection with a Tactile Resonance Sensor-Measurement Considerations and Clinical Setup.

Authors:  Anders P Åstrand; Britt M Andersson; Ville Jalkanen; Börje Ljungberg; Anders Bergh; Olof A Lindahl
Journal:  Sensors (Basel)       Date:  2017-10-26       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.