Impression technique for the assessment of oedema. Technical improvement and methodological evaluation of a new technique.

O Lindahl1, K A Angquist, S Odman.   

Abstract

A new instrument for the assessment of oedema based on the impression method is described. The measurement parameters are defined and the errors corresponding to the electrical and mechanical stability of the instrument are measured. The overall accuracy is calculated theoretically for the translocated volume. The accuracy and reproducibility are evaluated on plastic foam. The clinical procedure to measure oedema with this instrument is described. We show that the accuracy of the translocated volume parameter is very dependent on the overall stability of the instrument and that this instrument has an overall relative error of less than 7.3 per cent for a representative measurement. Experimental measurements on plastic foam show that the measurement parameters could be reproduced with standard deviations of less than 6 per cent and that the standard deviations for translocated volume are within the calculated overall relative error. Measurements on four patients with chronic oedema in an extremity show significantly different results on locations where pitting could be recognised compared to the contralateral nonoedematous extremity.

Entities:  

Mesh:

Year:  1991        PMID: 1813754     DOI: 10.1007/BF02446090

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  Noninvasive method for the assessment of subcutaneous oedema.

Authors:  M Mridha; S Odman
Journal:  Med Biol Eng Comput       Date:  1986-07       Impact factor: 2.602

2.  Strain energy descriptions of biological swelling. I: Single fluid compartment models.

Authors:  D K Bogen
Journal:  J Biomech Eng       Date:  1987-08       Impact factor: 2.097

Review 3.  Interstitial fluid pressure.

Authors:  A C Guyton; H J Granger; A E Taylor
Journal:  Physiol Rev       Date:  1971-07       Impact factor: 37.312

4.  Thixotropy in human skin.

Authors:  J B Finlay
Journal:  J Biomech       Date:  1978       Impact factor: 2.712

Review 5.  Interstitial fluid volume: local regulatory mechanisms.

Authors:  K Aukland; G Nicolaysen
Journal:  Physiol Rev       Date:  1981-07       Impact factor: 37.312

6.  Voluminometric estimation of the degree of lymphedema and its therapy by pneumatic compression.

Authors:  I Swedborg
Journal:  Scand J Rehabil Med       Date:  1977

7.  Interstitial fluid pressure. 3. Its effect on resistance to tissue fluid mobility.

Authors:  A C Guyton; K Scheel; D Murphree
Journal:  Circ Res       Date:  1966-08       Impact factor: 17.367

8.  Characterization of subcutaneous edema by mechanical impedance measurements.

Authors:  M Mridha; S Odman
Journal:  J Invest Dermatol       Date:  1985-12       Impact factor: 8.551

9.  Fluid translocation measurement. A method to study pneumatic compression treatment of postmastectomy lymphoedema.

Authors:  M Mridha; S Odman
Journal:  Scand J Rehabil Med       Date:  1989
  9 in total
  4 in total

1.  Prostate tissue stiffness as measured with a resonance sensor system: a study on silicone and human prostate tissue in vitro.

Authors:  Ville Jalkanen; Britt M Andersson; Anders Bergh; Börje Ljungberg; Olof A Lindahl
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

2.  Rat testis oedema measured with the impression technique: effects of hyaluronan, albumin, rat plasma and saline.

Authors:  O A Lindahl; A Bergh; J E Damber; K A Angquist
Journal:  Med Biol Eng Comput       Date:  1994-05       Impact factor: 2.602

3.  Impression technique for the assessment of oedema: comparison with a new tactile sensor that measures physical properties of tissue.

Authors:  O A Lindahl; S Omata
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

4.  Prostate Cancer Detection with a Tactile Resonance Sensor-Measurement Considerations and Clinical Setup.

Authors:  Anders P Åstrand; Britt M Andersson; Ville Jalkanen; Börje Ljungberg; Anders Bergh; Olof A Lindahl
Journal:  Sensors (Basel)       Date:  2017-10-26       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.