A catheter tactile sensor for measuring hardness of soft tissue: measurement in a silicone model and in an in vitro human prostate model.

A Eklund1, A Bergh, O A Lindahl.   

Abstract

Tissue hardness is related to tissue composition, and this is often changed by disease. It is therefore of interest to measure the hardness in an objective and non-invasive way. A tactile sensor based on a vibrating piezoelectric ceramic element in a feedback loop is described. When the sensor touches an object it produces a frequency shift related to the hardness of the object. The aim of this study was to develop an in vitro hardness measurement method using a catheter type version of the sensor. The method was evaluated in an established silicone tissue model and on human prostate tissue in vitro. A linear relationship was found with a high degree of explanation (R2 = 0.98) between a cone penetration hardness standard (DIN ISO 2137) applied to the silicone model and the corresponding frequency shift. The results from measurements on a human prostate tissue sample, fixed with formalin, showed that the relative hardness measured with the tactile sensor correlated (R = -0.96, p < 0.001, N = 60) with the proposed hardness related to the histological composition of the prostate tissue. The results indicated that hardness of prostate tissue, and maybe hardness of human tissue in general, can be expressed according to the cone penetration standard and that the hardness can be measured with this tactile sensory system. These findings hold the promise of further development of a non-invasive tool for hardness measurement in a clinical situation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10723900     DOI: 10.1007/bf02513357

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  8 in total

1.  Modeling of micturition characteristics based on prostatic stiffness modulation induced using hormones and adrenergic antagonists.

Authors:  O Sadao; C E Constantinou
Journal:  IEEE Trans Biomed Eng       Date:  1995-08       Impact factor: 4.538

Review 2.  Transrectal ultrasound of the prostate: innovations and future applications.

Authors:  R G Aarnink; H P Beerlage; J J De La Rosette; F M Debruyne; H Wijkstra
Journal:  J Urol       Date:  1998-05       Impact factor: 7.450

3.  Ultrasound reflections fail to reflect the histopathology of the prostate.

Authors:  W Tobocman; M I Resnick; T G Pretlow
Journal:  Prostate       Date:  1997-01-01       Impact factor: 4.104

4.  Comparative analysis of bladder wall compliance based on cystometry and biosensor measurements during the micturition cycle of the rat.

Authors:  T Watanabe; S Omata; J Z Lee; C E Constantinou
Journal:  Neurourol Urodyn       Date:  1997       Impact factor: 2.696

5.  A tactile sensor for detection of physical properties of human skin in vivo.

Authors:  O A Lindahl; S Omata; K A Angquist
Journal:  J Med Eng Technol       Date:  1998 Jul-Aug

6.  The stiffness of lymph nodes containing lung carcinoma metastases: a new diagnostic parameter measured by a tactile sensor.

Authors:  K Miyaji; A Furuse; J Nakajima; T Kohno; T Ohtsuka; K Yagyu; T Oka; S Omata
Journal:  Cancer       Date:  1997-11-15       Impact factor: 6.860

7.  Impression technique for the assessment of oedema: comparison with a new tactile sensor that measures physical properties of tissue.

Authors:  O A Lindahl; S Omata
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

8.  Random systematic versus directed ultrasound guided transrectal core biopsies of the prostate.

Authors:  K K Hodge; J E McNeal; M K Terris; T A Stamey
Journal:  J Urol       Date:  1989-07       Impact factor: 7.450

  8 in total
  11 in total

1.  Age-dependency of ocular parameters: a cross sectional study of young and elderly healthy subjects.

Authors:  G Jóhannesson; P Hallberg; K Ambarki; A Eklund; C Lindén
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-13       Impact factor: 3.117

2.  Underestimation of intraocular pressure after photorefractive keratectomy: a biomechanical analysis.

Authors:  Per Hallberg; Anders Eklund; Kenneth Santala; Timo Koskela; Olof Lindahl; Christina Lindén
Journal:  Med Biol Eng Comput       Date:  2006-07-26       Impact factor: 2.602

3.  Prostate tissue stiffness as measured with a resonance sensor system: a study on silicone and human prostate tissue in vitro.

Authors:  Ville Jalkanen; Britt M Andersson; Anders Bergh; Börje Ljungberg; Olof A Lindahl
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

4.  Assessing liver tumor stiffness by transient elastography.

Authors:  Ryota Masuzaki; Ryosuke Tateishi; Haruhiko Yoshida; Takahisa Sato; Takamasa Ohki; Tadashi Goto; Hideo Yoshida; Shinpei Sato; Yosuke Sugioka; Hitoshi Ikeda; Shuichiro Shiina; Takao Kawabe; Masao Omata
Journal:  Hepatol Int       Date:  2007-07-21       Impact factor: 6.047

5.  Prostate cancer detection with an improved resonance sensor system: parameter evaluation in a silicone model and on human prostate tissue in vitro.

Authors:  Peter Lindberg; Britt Andersson; Anders Bergh; Börje Ljungberg; Olof Lindahl
Journal:  Med Biol Eng Comput       Date:  2006-11-09       Impact factor: 2.602

6.  Viscoelastic Properties of Human Autopsy Brain Tissues as Biomarkers for Alzheimer's Diseases.

Authors:  Gabrielle E Lonsberry; Marla Gearing; Allan I Levey; Jaydev P Desai
Journal:  IEEE Trans Biomed Eng       Date:  2018-10-29       Impact factor: 4.538

7.  Evaluation of applanation resonator sensors for intra-ocular pressure measurement: results from clinical and in vitro studies.

Authors:  A Eklund; C Lindén; T Bäcklund; B M Andersson; O A Lindahl
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

8.  Edema and elasticity of a fronto-temporal decompressive craniectomy.

Authors:  Daikei Takada; Hidemasa Nagai; Kouzo Moritake; Yasuhiko Akiyama
Journal:  Surg Neurol Int       Date:  2012-01-21

9.  Repeatability and reproducibility of applanation resonance tonometry: a cross-sectional study.

Authors:  Laura Ottobelli; Paolo Fogagnolo; Paolo Frezzotti; Stefano De Cillà; Elena Vallenzasca; Maurizio Digiuni; Ruggiero Paderni; Ilaria Motolese; Simone Alex Bagaglia; Eduardo Motolese; Luca Rossetti
Journal:  BMC Ophthalmol       Date:  2015-04-10       Impact factor: 2.209

Review 10.  Microfabricated tactile sensors for biomedical applications: a review.

Authors:  Paola Saccomandi; Emiliano Schena; Calogero Maria Oddo; Loredana Zollo; Sergio Silvestri; Eugenio Guglielmelli
Journal:  Biosensors (Basel)       Date:  2014-11-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.