Literature DB >> 7565391

Lateral electron equilibrium and electron contamination in measurements of head-scatter factors using miniphantoms and brass caps.

X A Li1, M Soubra, J Szanto, L H Gerig.   

Abstract

The head-scatter factor (Sh) can be measured with a narrow miniphantom or a metal cap provided it is completely covered by the photon beam and its lateral size is thick enough to prevent electron contamination contributions. The effects of lateral electron equilibrium (LEE) and electron contamination on the Sh values were studied. The EGS4 Monte Carlo technique was used to calculate the minimum beam radii (rLEE) required to achieve complete LEE for photon beams ranging from 60Co to 24 MV. The measurement shows that the error introduced to the Sh value due to lateral electron disequilibrium is negligible. The radii of the miniphantoms or the sidewall thicknesses of the caps can be reduced below rLEE provided they are thick enough to prevent the effect of electron contamination.

Mesh:

Substances:

Year:  1995        PMID: 7565391     DOI: 10.1118/1.597508

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Dynamic conformal arc cranial stereotactic radiosurgery: implications of multileaf collimator margin on dose-volume metrics.

Authors:  J A Tanyi; E J Doss; C M Kato; D L Monaco; L ZMeng; Y Chen; C D Kubicky; C M Marquez; M Fuss
Journal:  Br J Radiol       Date:  2012-11       Impact factor: 3.039

2.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

3.  Output factor determination based on Monte Carlo simulation for small cone field in 10-MV photon beam.

Authors:  Kyohei Fukata; Satoru Sugimoto; Chie Kurokawa; Akito Saito; Tatsuya Inoue; Keisuke Sasai
Journal:  Radiol Phys Technol       Date:  2018-04-04

4.  Dosimetric characteristics of the small diameter BrainLab™ cones used for stereotactic radiosurgery.

Authors:  Gocha Khelashvili; James Chu; Aidnag Diaz; Julius Turian
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

5.  Sensitivity Analysis of the Integral Quality Monitoring System® Using Monte Carlo Simulation.

Authors:  Oluwaseyi M Oderinde; F C P du Plessis
Journal:  Comput Math Methods Med       Date:  2017-08-27       Impact factor: 2.238

6.  Design of mini phantom and measurement of cobalt-60 beam data parameters.

Authors:  S Senthilkumar; V Ramakrishnan
Journal:  J Med Phys       Date:  2008-07

7.  Collimator scatter factor: Monte Carlo and in-air measurements approaches.

Authors:  A Fogliata; A Stravato; G Reggiori; S Tomatis; J Würfel; M Scorsetti; L Cozzi
Journal:  Radiat Oncol       Date:  2018-07-11       Impact factor: 3.481

8.  Experimental investigation of TRS-483 reference dosimetry correction factors for Leksell Gamma Knife® Icon™ beams.

Authors:  Wille Häger; Vaiva Kaveckyte; Hamza Benmakhlouf
Journal:  Med Phys       Date:  2020-11-21       Impact factor: 4.071

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.