Dynamic conformal arc cranial stereotactic radiosurgery: implications of multileaf collimator margin on dose-volume metrics.

J A Tanyi1, E J Doss, C M Kato, D L Monaco, L ZMeng, Y Chen, C D Kubicky, C M Marquez, M Fuss.   

Abstract

OBJECTIVE: The effect of multileaf collimator (MLC) margin on target and normal tissue dose-volume metrics for intracranial stereotactic radiosurgery (SRS) was assessed.
METHODS: 118 intracranial lesions of 83 SRS patients formed the basis of this study. For each planning target volume (PTV), five separate treatment plans were generated with MLC margins of -1, 0, 1, 2 and 3 mm, respectively. Identical treatment planning parameters were employed with a median of five dynamic conformal arcs using the Varian/BrainLab high-definition MLC for beam shaping. Prescription dose (PD) was such that 22 Gy covered at least 95% of the PTV. Dose-volume and dose-response comparative metrics included conformity index, heterogeneity index, dose gradient, tumour control probability (TCP) and normal tissue complication probability (NTCP).
RESULTS: Target dose heterogeneity decreased with increasing MLC margin (p<0.001); mean heterogeneity index decreased from 70.4 ± 12.7 to 10.4 ± 2.2%. TCP decreased with increasing MLC margin (p<0.001); mean TCP decreased from 81.0 ± 2.3 to 62.2 ± 1.8%. Normal tissue dose fall-off increased with MLC margin (p<0.001); mean gradient increased from 3.1 ± 0.9 mm to 5.3 ± 0.7 mm. NTCP was optimal at 1 mm MLC margin. No unambiguous correlation was observed between NTCP and PTV volume. Plan delivery efficiency generally improved with larger margins (p<0.001); mean monitor unit per centigray of the PD decreased from 3.60 ± 1.30 to 1.56 ± 0.13. Conclusion Use of 1 mm MLC margins for dynamic conformal arc-based cranial radiosurgery resulted in optimal tumour control and normal tissue sparing. Clinical significance of these comparative findings warrants further investigation.

Entities:  

Mesh:

Year:  2012        PMID: 23091293      PMCID: PMC3500804          DOI: 10.1259/bjr/79414773

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  25 in total

1.  A simple and reliable index for scoring rival stereotactic radiosurgery plans.

Authors:  Thomas H Wagner; Francis J Bova; William A Friedman; John M Buatti; Lionel G Bouchet; Sanford L Meeks
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-11-15       Impact factor: 7.038

2.  Response corrections for solid-state detectors in megavoltage photon dosimetry.

Authors:  Z Yin; R P Hugtenburg; A H Beddoe
Journal:  Phys Med Biol       Date:  2004-08-21       Impact factor: 3.609

Review 3.  Tolerance of normal tissue to therapeutic irradiation.

Authors:  B Emami; J Lyman; A Brown; L Coia; M Goitein; J E Munzenrider; B Shank; L J Solin; M Wesson
Journal:  Int J Radiat Oncol Biol Phys       Date:  1991-05-15       Impact factor: 7.038

4.  Comparison of the penumbra between focused and nondivergent blocks--implications for multileaf collimators.

Authors:  P Biggs; J Capalucci; M Russell
Journal:  Med Phys       Date:  1991 Jul-Aug       Impact factor: 4.071

Review 5.  LINAC radiosurgery.

Authors:  W A Friedman
Journal:  Neurosurg Clin N Am       Date:  1990-10       Impact factor: 2.509

6.  Treatment volume and tissue tolerance.

Authors:  H R Withers; J M Taylor; B Maciejewski
Journal:  Int J Radiat Oncol Biol Phys       Date:  1988-04       Impact factor: 7.038

7.  Stereotactic LINAC radiosurgery.

Authors:  E Hitchcock; G Kitchen; E Dalton; B Pope
Journal:  Br J Neurosurg       Date:  1989       Impact factor: 1.596

Review 8.  Law and order of radiation sensitivity. Absolute versus relative.

Authors:  P Rubin
Journal:  Front Radiat Ther Oncol       Date:  1989

9.  Lateral electron equilibrium and electron contamination in measurements of head-scatter factors using miniphantoms and brass caps.

Authors:  X A Li; M Soubra; J Szanto; L H Gerig
Journal:  Med Phys       Date:  1995-07       Impact factor: 4.071

10.  Target dose versus extratarget dose in stereotactic radiosurgery.

Authors:  I Lax
Journal:  Acta Oncol       Date:  1993       Impact factor: 4.089

View more
  3 in total

1.  The effect of setup uncertainty on optimal dosimetric margin in LINAC-based stereotactic radiosurgery with dynamic conformal arc technique.

Authors:  Xiaoyu Duan; William Giles; John P Kirkpatrick; Fang-Fang Yin
Journal:  J Radiosurg SBRT       Date:  2019

2.  Prescription to 50-75% isodose line may be optimum for linear accelerator based radiosurgery of cranial lesions.

Authors:  Bo Zhao; Jian-Yue Jin; Ning Wen; Yimei Huang; M Salim Siddiqui; Indrin J Chetty; Samuel Ryu
Journal:  J Radiosurg SBRT       Date:  2014

3.  Radiation treatment planning with embedded dose escalation.

Authors:  William T Hrinivich; Todd R McNutt; Jeffrey J Meyer
Journal:  Radiat Oncol       Date:  2019-08-14       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.