Literature DB >> 7554641

The Otto Aufranc Award. Impact of gamma sterilization on clinical performance of polyethylene in the hip.

L C Sutula1, J P Collier, K A Saum, B H Currier, J H Currier, W M Sanford, M B Mayor, R E Wooding, D K Sperling, I R Williams.   

Abstract

Despite studies to determine their causes, significant variations in polyethylene acetabular component wear rates, radial cracking of component rims, and occasional delamination cannot be explained. A subsurface white band frequently occurs in such damaged components. These damaged components often are gamma sterilized. To date, the origin of the band and its effect on polyethylene chemical and mechanical properties, and hence, clinical performance, have not been confirmed, and correlations between radiation sterilization and clinical wear have not been made. By developing techniques for polyethylene retrieval testing and rating, chemical analysis, and mechanical analysis, this research has determined that gamma sterilization in air alters the chemical and mechanical properties of polyethylene over time, resulting in high subsurface oxidation, reduced ductility, and reduced strength. Gamma sterilization-induced oxidation is found to be most severe in the subsurface region of components, and coincides with zones of significantly reduced strength and ductility. This chemical and mechanical property degradation is time dependent and is not typically visible until after 3 years' postirradiation. The presence of the subsurface white band significantly correlates with clinical cracking and delamination observed in retrieved components. Wear of the retrieved components often is observed to have progressed into this heavily oxidized, weakened, and embrittled zone. A method for accelerated aging shows that irradiating in air causes oxidation damage in polyethylene components that is not seen with other sterilization methods. Modifications of gamma sterilization techniques to minimize this damage are discussed.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7554641

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  22 in total

1.  Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E.

Authors:  Ebru Oral; Steven D Christensen; Arnaz S Malhi; Keith K Wannomae; Orhun K Muratoglu
Journal:  J Arthroplasty       Date:  2006-06       Impact factor: 4.757

2.  Eleven-year results of the ABG I hip replacement.

Authors:  W Y Kim; B N Muddu
Journal:  Int Orthop       Date:  2006-03-07       Impact factor: 3.075

Review 3.  Biomaterials in orthopaedics.

Authors:  M Navarro; A Michiardi; O Castaño; J A Planell
Journal:  J R Soc Interface       Date:  2008-10-06       Impact factor: 4.118

4.  Highly cross-linked ultrahigh molecular weight polyethylene with improved fatigue resistance for total joint arthroplasty: recipient of the 2006 Hap Paul Award.

Authors:  Ebru Oral; Arnaz S Malhi; Keith K Wannomae; Orhun K Muratoglu
Journal:  J Arthroplasty       Date:  2008-06-10       Impact factor: 4.757

5.  Gamma inert sterilization: a solution to polyethylene oxidation?

Authors:  Francisco J Medel; Steven M Kurtz; William J Hozack; Javad Parvizi; James J Purtill; Peter F Sharkey; Daniel MacDonald; Matthew J Kraay; Victor Goldberg; Clare M Rimnac
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

6.  On the assessment of oxidative and microstructural changes after in vivo degradation of historical UHMWPE knee components by means of vibrational spectroscopies and nanoindentation.

Authors:  Francisco J Medel; Clare M Rimnac; Steven M Kurtz
Journal:  J Biomed Mater Res A       Date:  2009-05       Impact factor: 4.396

7.  THA with the ABG I prosthesis at 15 years. Excellent survival with minimal osteolysis.

Authors:  P N Baker; I A McMurtry; G Chuter; A Port; J Anderson
Journal:  Clin Orthop Relat Res       Date:  2010-07       Impact factor: 4.176

8.  CORR Insights(®): Surface Damage Is Not Reduced With Highly Crosslinked Polyethylene Tibial Inserts at Short-term.

Authors:  Harry A McKellop
Journal:  Clin Orthop Relat Res       Date:  2015-07-08       Impact factor: 4.176

9.  Gamma-irradiation sterilization in an inert environment: a partial solution.

Authors:  Daniel J Berry; Barbara H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

Review 10.  Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior.

Authors:  M C Sobieraj; C M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2008-12-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.