Literature DB >> 7503463

Time delay estimation using wavelet transform for pulsed-wave ultrasound.

X L Xu1, A H Tewfik, J F Greenleaf.   

Abstract

The windowed cross-correlation (WCC) technique has recently attracted attention in pulsed-wave (PW) ultrasound for measurement of tissue motion and blood flow velocity because of its performance advantages over the conventional Doppler method. The WCC measures tissue motion and blood flow velocity via estimation of time delays of backscattered signals in two consecutive echoes. In this paper, we propose a wavelet transform-based cross-correlation (WTCC) technique for the time delay estimation in PW ultrasound. The WTCC consists of three steps: (i) computing wavelet transforms (WTs) of received echoes, (ii) computing cross-correlations in the wavelet domain, and (iii) estimating the time delays by maximizing the estimated cross-correlations. Dyadic or continuous wavelets may be used in the proposed approach. The WTCC has a unique feature of using varying time-frequency windows in processing compared with the WCC which only uses a single fixed window. Our computer simulations show that, compared with the WCC, the WTCC provides a better estimation of time delays (lower failure rate and lower estimate error) and its performance is more consistent under various conditions, and more robust with window size. In the simulations, we also tested a specific continuous wavelet for the WTCC that was the emitted pulse itself and found the corresponding WTCC outperforms the WTCC with a regular dyadic wavelet.

Entities:  

Mesh:

Year:  1995        PMID: 7503463     DOI: 10.1007/bf02584460

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  5 in total

1.  Flow velocity profile via time-domain correlation: error analysis and computer simulation.

Authors:  S G Foster; P M Embree; W R O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1990       Impact factor: 2.725

2.  Volumetric blood flow via time-domain correlation: experimental verification.

Authors:  P M Embree; W R O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1990       Impact factor: 2.725

3.  Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review.

Authors:  I A Hein; W R O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1993       Impact factor: 2.725

4.  Time domain formulation of pulse-Doppler ultrasound and blood velocity estimation by cross correlation.

Authors:  O Bonnefous; P Pesqué
Journal:  Ultrason Imaging       Date:  1986-04       Impact factor: 1.578

5.  Comparison of the performance of the RF cross correlation and Doppler autocorrelation technique to estimate the mean velocity of simulated ultrasound signals.

Authors:  A P Hoeks; T G Arts; P J Brands; R S Reneman
Journal:  Ultrasound Med Biol       Date:  1993       Impact factor: 2.998

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.