Time domain formulation of pulse-Doppler ultrasound and blood velocity estimation by cross correlation.

O Bonnefous, P Pesqué.   

Abstract

The Doppler effect is usually described as a frequency shift of the backscattered signals from moving targets with respect to the frequency transmitted. Recently, real-time blood flow imaging has become possible thanks to the development of a new velocity estimator based on phase-shift measurements of successive echoes. However, this method suffers from the well-known limitations of pulse-Doppler instruments. A new formulation is presented which describes the pulse-Doppler effect on the successive echoes from a cloud of moving targets as a progressive translation in time due to the displacement of the scatterers between two excitations. This approach allows us to generate efficiently computer-simulated data in order to evaluate accurately the various processing techniques. Furthermore, it leads to a novel class of velocity estimators in the time domain which measure the time shifts which are proportional to the local blood velocity. Among them, the cross correlation of the received rf signals turns out to be well suited. A local cross-correlation function is first calculated from a consecutive pair of range-gated echoes and the time shift is then determined by searching for the time position with the maximum correlation. The time-correlation technique is shown to provide accurate velocity profiles with broadband transducers. Moreover, the classical velocity limitation of pulse-Doppler is overcome because there is no ambiguity in measuring a time shift instead of a phase shift. These major advantages should make quantitative flow mapping possible and more reliable.

Mesh:

Year:  1986        PMID: 2946098     DOI: 10.1177/016173468600800201

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  33 in total

1.  [Realtime elastography. A new ultrasound procedure for the reconstruction of tissue elasticity].

Authors:  H Frey
Journal:  Radiologe       Date:  2003-10       Impact factor: 0.635

2.  Vectorial measurement of blood velocity by means of ultrasound.

Authors:  D Dotti; R Lombardi; P Piazzi
Journal:  Med Biol Eng Comput       Date:  1992-03       Impact factor: 2.602

3.  Volumetric elasticity imaging with a 2-D CMUT array.

Authors:  Ted G Fisher; Timothy J Hall; Satchi Panda; Michael S Richards; Paul E Barbone; Jingfeng Jiang; Jeff Resnick; Steve Barnes
Journal:  Ultrasound Med Biol       Date:  2010-06       Impact factor: 2.998

4.  Ultrasonic tracking of acoustic radiation force-induced displacements in homogeneous media.

Authors:  Mark L Palmeri; Stephen A McAleavey; Gregg E Trahey; Kathryn R Nightingale
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-07       Impact factor: 2.725

5.  Functional tissue pulsatility imaging of the brain during visual stimulation.

Authors:  John C Kucewicz; Barbrina Dunmire; Daniel F Leotta; Heracles Panagiotides; Marla Paun; Kirk W Beach
Journal:  Ultrasound Med Biol       Date:  2007-05       Impact factor: 2.998

6.  MUlti-Dimensional Spline-Based Estimator (MUSE) for motion estimation: algorithm development and initial results.

Authors:  Francesco Viola; Ryan L Coe; Kevin Owen; Drake A Guenther; William F Walker
Journal:  Ann Biomed Eng       Date:  2008-09-20       Impact factor: 3.934

7.  Time delay estimation using wavelet transform for pulsed-wave ultrasound.

Authors:  X L Xu; A H Tewfik; J F Greenleaf
Journal:  Ann Biomed Eng       Date:  1995 Sep-Oct       Impact factor: 3.934

8.  Functional ultrasound imaging of the brain.

Authors:  Emilie Macé; Gabriel Montaldo; Ivan Cohen; Michel Baulac; Mathias Fink; Mickael Tanter
Journal:  Nat Methods       Date:  2011-07-03       Impact factor: 28.547

Review 9.  Developments in cardiovascular ultrasound: Part 1: Signal processing and instrumentation.

Authors:  P J Fish; P R Hoskins; C Moran; W N McDicken
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

10.  Derivation of correlation coefficient formula for determination of Doppler angle using time domain correlation ultrasonic flowmeter.

Authors:  I Güler
Journal:  J Med Syst       Date:  1997-04       Impact factor: 4.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.