Literature DB >> 7347122

Image distortion in rotational panoramic radiography. IV. Object morphology; outer contours.

G Tronje, U Welander, W D McDavid, C R Morris.   

Abstract

On films exposed with rotational panoramic radiography, distortion effects are often apparent. The distortion of the outer contour of three-dimensional model objects jas been analysed mathematically. The applied mathematical expressions for coordinate transformation between object and film were confirmed experimentally. The distortion of the outer contour is dependent on the basic form of the object; the more rounded the object is, the less marked is the distortion. It is concluded that for practical clinical purposes the correctly exposed panoramic film is reliable when the form of rounded objects is assessed.

Mesh:

Year:  1981        PMID: 7347122     DOI: 10.1177/028418518102200613

Source DB:  PubMed          Journal:  Acta Radiol Diagn (Stockh)        ISSN: 0567-8056


  6 in total

1.  Reliability of computational measurement of the condyles on digital panoramic radiographs.

Authors:  A Momjian; D Courvoisier; S Kiliaridis; P Scolozzi
Journal:  Dentomaxillofac Radiol       Date:  2011-10       Impact factor: 2.419

2.  Object position and image magnification in dental panoramic radiography: a theoretical analysis.

Authors:  H Devlin; J Yuan
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

3.  Impact of malpositioning on panoramic radiography in implant dentistry.

Authors:  Björn Riecke; Reinhard E Friedrich; Dirk Schulze; Clemens Loos; Marco Blessmann; Max Heiland; Johannes Wikner
Journal:  Clin Oral Investig       Date:  2014-07-31       Impact factor: 3.573

4.  Obstacles in spatial evaluation of CBCT-reformatted panoramic imaging.

Authors:  Johannes Wikner; Reinhard E Friedrich; Ashkan Rashad; Dirk Schulze; Henning Hanken; Max Heiland; Alexander Gröbe; Björn Riecke
Journal:  Dentomaxillofac Radiol       Date:  2016-03-09       Impact factor: 2.419

5.  The magnification in the lower third and second molar region in the digital panoramic radiographs.

Authors:  Giedrė Trakiniene; Antanas Šidlauskas; Vilma Švalkauskienė; Dalia Smailienė; Julija Urbonė
Journal:  J Forensic Dent Sci       Date:  2017 May-Aug

6.  Comparison of Orthopantomogram and Lateral Cephalogram for Mandibular Measurements.

Authors:  S Saravana Kumar; V Thailavathy; Daya Srinivasan; Divya Loganathan; J Yamini
Journal:  J Pharm Bioallied Sci       Date:  2017-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.