Literature DB >> 26959644

Obstacles in spatial evaluation of CBCT-reformatted panoramic imaging.

Johannes Wikner1, Reinhard E Friedrich1, Ashkan Rashad1, Dirk Schulze2, Henning Hanken1, Max Heiland1, Alexander Gröbe1, Björn Riecke1.   

Abstract

OBJECTIVES: Conventional panoramic radiography (cPR) underlines procedure-related limitations in the display of objects. CBCT is presumed to overcome these constraints. To virtualize a cPR view, reformatted panoramic images (rPIs) can be generated. This study evaluated the rPI with regard to its susceptibility to sterical object deposition in comparison with cPR.
METHODS: A specially developed implant model with dental implants each of 4.0-mm diameter and 11.0-mm length was depositioned by shift, rotation and tilt of 5.00 mm (±0.01 mm) of horizontal shift and 5.0° (±0.167°), respectively, on a highly precise goniometer rotation table, and cPRs and rPIs were generated. Automated evaluation of the cPRs was carried out using a specially developed software. rPIs were processed and analyzed by a semi-automated image analysis.
RESULTS: Object deposition lead to distortive effects in the rPI analogue to cPR, but they appear in display only. Objects illustrated in the rPI were dimensionally correct, but sterical relations are elusive. Results are obtained for the horizontal shift, declination and reclination, lateral tilt and rotation.
CONCLUSIONS: Distortions within the rPI represent the illustration of the hyperbolic-shaped layer out of the three-dimensional data set. With this study, we demonstrated these procedure-related inherent but practically underestimated consequences. Effects of sterical object malpositioning must be compensated by the observer by adequate virtual adjustment of the processed layer. Accurate virtual adjustment leads to vertical dimensions. Sterical relations, e.g. angulation of two objects, are irretraceable unless precisely referenced.

Entities:  

Keywords:  cone-beam computed tomography; dental implant; multiplanar reconstructions; panoramic radiography; reformatted panoramic image

Mesh:

Substances:

Year:  2016        PMID: 26959644      PMCID: PMC4846180          DOI: 10.1259/dmfr.20150436

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  15 in total

1.  Development of a compact computed tomographic apparatus for dental use.

Authors:  Y Arai; E Tammisalo; K Iwai; K Hashimoto; K Shinoda
Journal:  Dentomaxillofac Radiol       Date:  1999-07       Impact factor: 2.419

2.  Precision and accuracy of measurements in digital panoramic radiography.

Authors:  R Schulze; F Krummenauer; F Schalldach; B d'Hoedt
Journal:  Dentomaxillofac Radiol       Date:  2000-01       Impact factor: 2.419

3.  Selection criteria for dental implant site imaging: a position paper of the American Academy of Oral and Maxillofacial radiology.

Authors:  D A Tyndall; S L Brooks
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2000-05

4.  An in vitro comparison of subjective image quality of panoramic views acquired via 2D or 3D imaging.

Authors:  P Pittayapat; D Galiti; Y Huang; K Dreesen; M Schreurs; P Couto Souza; I R F Rubira-Bullen; F H Westphalen; R Pauwels; G Kalema; G Willems; R Jacobs
Journal:  Clin Oral Investig       Date:  2012-03-01       Impact factor: 3.573

5.  Linear accuracy and reliability of volume data sets acquired by two CBCT-devices and an MSCT using virtual models: a comparative in-vitro study.

Authors:  Johannes Wikner; Henning Hanken; Christine Eulenburg; Max Heiland; Alexander Gröbe; Alexandre Thomas Assaf; Björn Riecke; Reinhard E Friedrich
Journal:  Acta Odontol Scand       Date:  2015-05-02       Impact factor: 2.331

6.  Object position and image magnification in dental panoramic radiography: a theoretical analysis.

Authors:  H Devlin; J Yuan
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

7.  Planning of dental implant size with digital panoramic radiographs, CBCT-generated panoramic images, and CBCT cross-sectional images.

Authors:  Leticia Ruhland Correa; Rubens Spin-Neto; Andreas Stavropoulos; Lars Schropp; Heloísa Emília Dias da Silveira; Ann Wenzel
Journal:  Clin Oral Implants Res       Date:  2013-02-26       Impact factor: 5.977

8.  Impact of malpositioning on panoramic radiography in implant dentistry.

Authors:  Björn Riecke; Reinhard E Friedrich; Dirk Schulze; Clemens Loos; Marco Blessmann; Max Heiland; Johannes Wikner
Journal:  Clin Oral Investig       Date:  2014-07-31       Impact factor: 3.573

9.  Image distortion in rotational panoramic radiography. VI. Distortion effects in sliding systems.

Authors:  G Tronje; U Welander; W D McDavid; C R Morris
Journal:  Acta Radiol Diagn (Stockh)       Date:  1982

10.  Image distortion in rotational panoramic radiography. IV. Object morphology; outer contours.

Authors:  G Tronje; U Welander; W D McDavid; C R Morris
Journal:  Acta Radiol Diagn (Stockh)       Date:  1981
View more
  1 in total

1.  Preauricular Swelling Mimicking a Tumour: Dissolution of Mandibular Capitulum Following Trauma in a 15-Year Old Child.

Authors:  Reinhard E Friedrich; Felix K Kohlrusch
Journal:  In Vivo       Date:  2020 May-Jun       Impact factor: 2.155

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.