Literature DB >> 7290015

Optimal x-ray spectra for screen-film mammography.

R J Jennings, R J Eastgate, M P Siedband, D L Ergun.   

Abstract

Theoretical and experimental techniques have been used to study optimal x-ray for screen-film mammography. A simple model of mammographic imaging predicts optimum x-ray energies which are significantly higher than the K-characteristic energies of Mo. A subjective comparison of x-ray spectra from Mo-anode and W-anode tubes indicates that spectra produced by a W-anode tube filtered with materials of atomic number just above that of Mo are more suitable for screen-film mammography than spectra produced by the Mo-anode/Mo-filter system. The imaging performance of K-edge filtered, W-anode tube spectra was compared to the performance of Mo-anode spectra using phantom measurements and mastectomy specimen radiography. It was shown that optimal W-anode spectra can produce equal contrast with an exposure reduction of a factor of two to three, a dose reduction of a factor of two, and equal or reducing tube loading, compared to Mo-anode spectra. A computer simulation was carried out to extend the initial, monoenergetic theory to the case of real, polychromatic sources. The effects of varying filter material and thickness, tube operating potential, and breast thickness were all studied. Since W-anode x-ray tubes are considered to be better for Xerox mammography than Mo-anode tubes, this study has shown that both Xerox and screen-film techniques can be performed optimally with a single, properly designed, W-anode x-ray tube.

Mesh:

Year:  1981        PMID: 7290015     DOI: 10.1118/1.595021

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Near monochromatic X-rays for digital slot-scan mammography: initial findings.

Authors:  Felix Diekmann; S Diekmann; K Richter; U Bick; T Fischer; R Lawaczeck; W-R Press; K Schön; H-J Weinmann; V Arkadiev; A Bjeoumikhov; N Langhoff; J Rabe; P Roth; J Tilgner; R Wedell; M Krumrey; U Linke; G Ulm; B Hamm
Journal:  Eur Radiol       Date:  2004-06-30       Impact factor: 5.315

2.  Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system.

Authors:  Paula Toroi; Federica Zanca; Kenneth C Young; Chantal van Ongeval; Guy Marchal; Hilde Bosmans
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 5.315

3.  A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data.

Authors:  Stefano Young; Predrag R Bakic; Kyle J Myers; Robert J Jennings; Subok Park
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

4.  Determination of linear x-ray attenuation coefficients of pathological brain tissues and use of filters in tissue contrast enhancement in computed tomography.

Authors:  M Erdem Sagsoz; Fazlı Erdogan; Salih Z Erzeneoglu; İhsan Yuce
Journal:  Eurasian J Med       Date:  2010-08

5.  Image Quality and Radiation Dose for Fibrofatty Breast using Target/filter Combinations in Two Digital Mammography Systems.

Authors:  Khaled Alkhalifah; Akram Asbeutah; Ajit Brindhaban
Journal:  J Clin Imaging Sci       Date:  2020-09-07

6.  Radiosensitization of Prostate Cancers In Vitro and In Vivo to Erbium-filtered Orthovoltage X-rays Using Actively Targeted Gold Nanoparticles.

Authors:  Allison M Khoo; Sang Hyun Cho; Francisco J Reynoso; Maureen Aliru; Kathryn Aziz; Monica Bodd; Xi Yang; Md F Ahmed; Selcuk Yasar; Nivedh Manohar; Jongmin Cho; Ramesh Tailor; Howard D Thames; Sunil Krishnan
Journal:  Sci Rep       Date:  2017-12-22       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.