Literature DB >> 7207423

Lesion detection and signal-to-noise ratio in CT images.

P F Judy, R G Swensson, M Szulc.   

Abstract

This study measured observers' ability to detect and locate focal lesions on simulated CT images. The difficulty of the detection task was manipulated by changing the difference in attenuation between the lesion and its background (contrast), the random variation in the CT values (noise) or the lesion's size. The human observers' performance was compared to that of matched filter detector, modified to include the effects introduced by the display window and the uncertainty about the lesion's location on the image. Changes in lesion contrast, lesion size and noise produced large variations in both the lesion signal-to-noise ratio (a measure of the matched filter detector's performance) and estimated measures of the observer's detection and localization ability. Changes in observers' performance were closely related to changes in lesion signal-to-noise ratio. Generally, changes in lesion contrast, lesion size or noise that produced similar values of lesion signal-to-noise ratios had equivalent effects upon the observers' performance.

Entities:  

Mesh:

Year:  1981        PMID: 7207423     DOI: 10.1118/1.594903

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

Review 3.  Collimator design for single photon emission tomography.

Authors:  S C Moore; K Kouris; I Cullum
Journal:  Eur J Nucl Med       Date:  1992

4.  Comparison of a PACS workstation with conventional film for interpretation of neonatal examinations: a paired comparison study.

Authors:  E A Franken; W L Smith; K S Berbaum; S C Kao; Y Sato
Journal:  Pediatr Radiol       Date:  1991

Review 5.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

Review 6.  Task-based measures of image quality and their relation to radiation dose and patient risk.

Authors:  Harrison H Barrett; Kyle J Myers; Christoph Hoeschen; Matthew A Kupinski; Mark P Little
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

7.  Unified snr analysis of medical imaging systems.

Authors:  Robert F Wagner; David G Brown
Journal:  Phys Med Biol       Date:  1985-06       Impact factor: 3.609

8.  More Unified Analysis of Medical Imaging System SNR Characteristics.

Authors:  Robert F Wagner; David G Brown
Journal:  Proc SPIE Int Soc Opt Eng       Date:  1984-06-15

9.  Two-state versus continuous-state stimulus representations: a test based on attentional constraints.

Authors:  M L Shaw; R M Mulligan; L D Stone
Journal:  Percept Psychophys       Date:  1983-04

10.  Detection of noisy visual targets: models for the effects of spatial uncertainty and signal-to-noise ratio.

Authors:  R G Swensson; P F Judy
Journal:  Percept Psychophys       Date:  1981-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.