Anchorage of femoral implants visualized by modified computed tomography.

P Seitz, P Rüegsegger.   

Abstract

Metallic implants produce a great deal of artifacts in standard CT images. These artifacts cover tissue structures and impede visualization of the anchorage of the implant within the bone. Thus a modified CT procedure has been developed to permit reconstructions free from artifacts. It is an iterative procedure using a maximum of measured projection data. Using this modified CT technique, the anchorage of a titanium-alloy femoral prosthesis implanted without cement was examined. Good contact of the implant with the cortical bone has documented. This promises good initial stability. The CT examinations were performed by using a special-purpose CT scanner. It is hoped that the modified CT technique will allow a quantification of bony tissue in the close vicinity of implants and thus provide a non-invasive procedure that will allow the long-term stability of implants to be evaluated.

Mesh:

Substances:

Year:  1982        PMID: 7159198     DOI: 10.1007/bf00381666

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  5 in total

1.  The exponential edge-gradient effect in x-ray computed tomography.

Authors:  P M Joseph; R D Spital
Journal:  Phys Med Biol       Date:  1981-05       Impact factor: 3.609

2.  Properties of implant alloys for artificial hip joints.

Authors:  M Semilitsch; H G Willert
Journal:  Med Biol Eng Comput       Date:  1980-07       Impact factor: 2.602

3.  Concept and material properties of a cementless hip prosthesis system with Al2O3 ceramic ball heads and wrought Ti-6Al-4V stems.

Authors:  K Zweymüller; M Semlitsch
Journal:  Arch Orthop Trauma Surg       Date:  1982

4.  Quantitative bone mineral analysis using dual energy computed tomography.

Authors:  H K Genant; D Boyd
Journal:  Invest Radiol       Date:  1977 Nov-Dec       Impact factor: 6.016

5.  Computed tomography reconstruction from hollow projections: an application to in vivo evaluation of artificial hip joints.

Authors:  T Hinderling; P Rüegsegger; M Anliker; C Dietschi
Journal:  J Comput Assist Tomogr       Date:  1979-02       Impact factor: 1.826

  5 in total
  3 in total

1.  [Liability problems in endoprosthetics].

Authors:  H Rettig
Journal:  Unfallchirurgie       Date:  1986-02

2.  Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.

Authors:  Matthew J Meagher; Rachna N Parwani; Amarjit S Virdi; Dale R Sumner
Journal:  J Orthop Res       Date:  2017-10-04       Impact factor: 3.494

3.  Disuse osteoporosis in patients with total hip prostheses.

Authors:  P Rüegsegger; P Seitz; N Gschwend; L Dubs
Journal:  Arch Orthop Trauma Surg       Date:  1986
  3 in total