Literature DB >> 7421346

Properties of implant alloys for artificial hip joints.

M Semilitsch, H G Willert.   

Abstract

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7421346     DOI: 10.1007/bf02443329

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  3 in total

1.  Metallurgical and clinical experience with cast and forged cobalt/chromium base implant metals of compound construction for artificial joint endoprostheses.

Authors:  M Semlitsch
Journal:  Reconstr Surg Traumatol       Date:  1976

2.  Fatigue behavior of type 316 stainless steel under simulated body conditions.

Authors:  K R Wheeler; L A James
Journal:  J Biomed Mater Res       Date:  1971-05

3.  Corrosion behavior of cast and forged cobalt-based alloys for double-alloy joint endoprostheses.

Authors:  P Süry; M Semlitsch
Journal:  J Biomed Mater Res       Date:  1978-09
  3 in total
  6 in total

Review 1.  New Developments of Ti-Based Alloys for Biomedical Applications.

Authors:  Yuhua Li; Chao Yang; Haidong Zhao; Shengguan Qu; Xiaoqiang Li; Yuanyuan Li
Journal:  Materials (Basel)       Date:  2014-03-04       Impact factor: 3.623

2.  Anchorage of femoral implants visualized by modified computed tomography.

Authors:  P Seitz; P Rüegsegger
Journal:  Arch Orthop Trauma Surg       Date:  1982

Review 3.  Tribochemical Characterization and Tribocorrosive Behavior of CoCrMo Alloys: A Review.

Authors:  Wei Quan Toh; Xipeng Tan; Ayan Bhowmik; Erjia Liu; Shu Beng Tor
Journal:  Materials (Basel)       Date:  2017-12-26       Impact factor: 3.623

4.  A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using Coffin/Manson Fatigue Model.

Authors:  Branislav Krivokapic; Zoran Blagojevic; Dora Selesi; Teodor Atanackovic; Stevan Pilipovic; Zoran Bascarevic; Vladan Stevanovic
Journal:  Biomed Res Int       Date:  2018-05-23       Impact factor: 3.411

5.  Standardized Loads Acting in Hip Implants.

Authors:  Georg Bergmann; Alwina Bender; Jörn Dymke; Georg Duda; Philipp Damm
Journal:  PLoS One       Date:  2016-05-19       Impact factor: 3.240

6.  A Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac.

Authors:  Mohammad Taghi Bahreyni Toossi; Marziyeh Behmadi; Mahdi Ghorbani; Hamid Gholamhosseinian
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

  6 in total