Literature DB >> 422792

Computed tomography reconstruction from hollow projections: an application to in vivo evaluation of artificial hip joints.

T Hinderling, P Rüegsegger, M Anliker, C Dietschi.   

Abstract

The long-term mechanical stability of total hip arthroplasties limits the application of this widely used surgical procedure in cases of severe coxarthroses. A noninvasive method of assessing the tissue distribution in the vicinity of the implant--bone interface is needed to identify early signs of implant loosening and to evaluate new prosthetic solutions. In order to develop such a method, a modified computed tomography technique has been devised that yields cross-sectional images without the usual artifacts caused by metallic implants. This technique provides information on bone mineral and bone cement distributions as well as on the precise position and orientation of the implant within the femur shaft. Results obtained from excised human femurs and preliminary data from measurements on patients made 3 months postoperatively reveal that the bone cement distribution is much less favorable than is indicated by radiographs.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 422792

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  7 in total

1.  Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

Authors:  Wei Zhou; David J Bartlett; Felix E Diehn; Katrina N Glazebrook; Amy L Kotsenas; Rickey E Carter; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2019-04       Impact factor: 6.016

2.  U-net based metal segmentation on projection domain for metal artifact reduction in dental CT.

Authors:  Mohamed A A Hegazy; Myung Hye Cho; Min Hyoung Cho; Soo Yeol Lee
Journal:  Biomed Eng Lett       Date:  2019-04-29

3.  Densitometric evaluation of bone-prosthetic counterface in hip and knee arthroplasty with modern implants.

Authors:  Andrea Cozzi Lepri; Marco Giorgini; Carla Signorini; Christian Carulli; Roberto Civinini; Maria Luisa Brandi; Massimo Innocenti
Journal:  Clin Cases Miner Bone Metab       Date:  2016-10-05

4.  Anchorage of femoral implants visualized by modified computed tomography.

Authors:  P Seitz; P Rüegsegger
Journal:  Arch Orthop Trauma Surg       Date:  1982

5.  Improved imaging of the cervico-thoracic junction in computed tomography.

Authors:  Pyong Kon Cho; Young Hen Lee; You Hyun Kim; Jong Hak Choi; Dong Chul Shin; Tae Kyu Choi; Jang Seob Kim; Ki Hyun Kim; Sun Ung Kim
Journal:  Yonsei Med J       Date:  2008-02-29       Impact factor: 2.759

6.  CT metal artifact reduction algorithms: Toward a framework for objective performance assessment.

Authors:  J Y Vaishnav; B Ghammraoui; M Leifer; R Zeng; L Jiang; K J Myers
Journal:  Med Phys       Date:  2020-06-05       Impact factor: 4.071

7.  MR image based approach for metal artifact reduction in X-ray CT.

Authors:  Andras Anderla; Dubravko Culibrk; Gaspar Delso; Milan Mirkovic
Journal:  ScientificWorldJournal       Date:  2013-11-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.