New latex agglutination test for rapid determination of rubella immune status.

A S Weissfeld, A C Sonnenwirth.   

Abstract

A prototype rubella latex agglutination card assay (Hynson, Westcott and Dunning, Baltimore, Md.) was compared with a standard hemagglutination inhibition test for the detection of rubella antibodies in 500 sera. The sensitivity and specificity of the latex agglutination assay were 100% and 94%, respectively. This assay did not require pretreatment of serum, and the entire assay could be performed in 10 min.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7153349      PMCID: PMC272514          DOI: 10.1128/jcm.16.5.971-972.1982

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  3 in total

1.  Comparison of hemagglutination inhibition test and enzyme-linked immunosorbent assay for determining antibody to rubella virus.

Authors:  I C Shekarchi; J L Sever; N Tzan; A Ley; L C Ward; D Madden
Journal:  J Clin Microbiol       Date:  1981-05       Impact factor: 5.948

2.  Evaluation of commercially available diagnostic test kits for rubella.

Authors:  G A Castellano; D L Madden; G T Hazzard; C S Cleghorn; D V Vails; A C Ley; N R Tzan; J L Sever
Journal:  J Infect Dis       Date:  1981-04       Impact factor: 5.226

3.  Enzyme-linked immunosorbent assay for measurement of antibody against cytomegalovirus and rubella virus in a single serum dilution.

Authors:  A M van Loon; J T van der Logt; J van der Veen
Journal:  J Clin Pathol       Date:  1981-06       Impact factor: 3.411

  3 in total
  7 in total

1.  Evaluation of a new latex test and a new enzyme immunoassay for determination of rubella immunity.

Authors:  A E Simor; R Chua; D E Low
Journal:  J Clin Microbiol       Date:  1988-08       Impact factor: 5.948

2.  Differences in antibody responses with rapid agglutination tests for the detection of rubella antibodies.

Authors:  M A Chernesky; D J DeLong; J B Mahony; S Castriciano
Journal:  J Clin Microbiol       Date:  1986-04       Impact factor: 5.948

3.  Comparative evaluation of commercial rubella virus antibody kits.

Authors:  R A Wittenburg; M A Roberts; L B Elliott; L M Little
Journal:  J Clin Microbiol       Date:  1985-02       Impact factor: 5.948

4.  Evaluation of a latex agglutination test for screening antibodies to rubella virus.

Authors:  P León; F de Ory; C Domingo; J A López; J M Echevarría
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1988-04       Impact factor: 3.267

5.  Evaluation of a latex agglutination test for detection of antibodies to rubella virus in selected sera.

Authors:  S Freeman; L Clark; N Dumas
Journal:  J Clin Microbiol       Date:  1983-07       Impact factor: 5.948

6.  Detection of rubella virus immunoglobulin G (IgG) and IgM antibodies in whole blood on Whatman paper: comparison with detection in sera.

Authors:  V Punnarugsa; V Mungmee
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

7.  Use of enzyme immunoassays and the latex agglutination test to measure the temporal appearance of immunoglobulin G and M antibodies after natural infection or immunization with rubella virus.

Authors:  J M Meegan; B K Evans; D M Horstmann
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.