Literature DB >> 7107853

Evaluation of the MICUR system for quantitative antimicrobial susceptibility testing: a multiphasic comparison with reference methods.

R N Jones, A L Barry, J Bigelow, T L Gavan, C Thornsberry.   

Abstract

Four laboratories participated in a three-phase study to evaluate the MICUR antimicrobial broth microdilution system (Boehringer Mannheim Diagnostics, Inc., Houston, Tex.). The dried-antimicrobial agent MICUR system was compared with a reference broth microdilution method (National Committee for Clinical Laboratory Standards) by using 304 recently isolated clinical strains and two collections of stock or challenge organisms. Of 7,092 minimum inhibitory concentration (MIC) datum pairs derived from the clinical isolates, 96.6% were within an acceptable (+/- 1 log2 dilution) range. MICUR MICs agreed with the reference broth microdilution method MICs in 95.3% of 6,840 MIC pair determinations performed on stock or challenge cultures. The MICUR intralaboratory reproducibility within +/- 1 log2 dilution step for the clinical isolates was 98.4%. The MICUR intralaboratory and interlaboratory reproducibilities for 26 stock cultures were 98.4 and 95.1%, respectively. For 180 challenge cultures (4,199 MIC pairs) which were included in the MICUR testing to provide a wide variety of antimicrobial susceptibility and resistance patterns, the results for 92.5% were in close agreement with the reference broth microdilution results. No specific resistance mechanism went unrecognized by this new commercial system. The MICUR system gives comparable MIC results when evaluated against the reference broth microdilution method, and it would be acceptable for use in clinical microbiology laboratories.

Mesh:

Substances:

Year:  1982        PMID: 7107853      PMCID: PMC272312          DOI: 10.1128/jcm.16.1.153-163.1982

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Evaluation of the Sceptor microdilution antibiotic susceptibility testing system: a collaborative investigation.

Authors:  R N Jones; C Thornsberry; A L Barry; T L Gavan
Journal:  J Clin Microbiol       Date:  1981-01       Impact factor: 5.948

2.  Evaluation of the micro-media system for quantitative antimicrobial drug susceptibility testing: a collaborative study.

Authors:  A L Barry; R N Jones; T L Gavan
Journal:  Antimicrob Agents Chemother       Date:  1978-01       Impact factor: 5.191

3.  Evaluation of the sensititre microdilution antibiotic susceptibility system against recent clinical isolates: three-laboratory collaborative study.

Authors:  R N Jones; T L Gavan; A L Barry
Journal:  J Clin Microbiol       Date:  1980-04       Impact factor: 5.948

4.  Evaluation of the Sensititre system for quantitative antimicrobial drug susceptibility testing: a collaborative study.

Authors:  T L Gavan; R N Jones; A L Barry
Journal:  Antimicrob Agents Chemother       Date:  1980-03       Impact factor: 5.191

  4 in total
  4 in total

1.  Evaluation of the MicroScan antimicrobial susceptibility system with the autoSCAN-4 automated reader.

Authors:  C N Baker; S A Stocker; D L Rhoden; C Thornsberry
Journal:  J Clin Microbiol       Date:  1986-01       Impact factor: 5.948

2.  Automated reading of a microtitre plate: preliminary evaluation in antimicrobial susceptibility tests and Enterobacteriaceae identification.

Authors:  R J Courcol; H Deleersnyder; M Roussel-Delvallez; G R Martin
Journal:  J Clin Pathol       Date:  1983-03       Impact factor: 3.411

3.  Evaluation of the Micur microdilution systems for antibiotic susceptibility testing of gram-negative and gram-positive bacteria.

Authors:  F Kayser; K Machka; L Wieczorek; D Banauch; W Bablok; I Braveny
Journal:  Eur J Clin Microbiol       Date:  1982-12       Impact factor: 3.267

4.  Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Authors:  J M Boyce; L S Lytle; D A Walsh
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

  4 in total