Literature DB >> 6338058

Automated reading of a microtitre plate: preliminary evaluation in antimicrobial susceptibility tests and Enterobacteriaceae identification.

R J Courcol, H Deleersnyder, M Roussel-Delvallez, G R Martin.   

Abstract

An automated microELISA Reader was evaluated for its ability to read and interpret microtitre plates. A total of 309 microtitre plates were investigated by automated and visual methods. There was disagreement between the methods in one hundred and twelve (0.6%) wells. However agreements between the two methods for susceptibility tests and Enterobacteriaceae identification were respectively 98.8% and 89.3%.

Mesh:

Substances:

Year:  1983        PMID: 6338058      PMCID: PMC498209          DOI: 10.1136/jcp.36.3.341

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  11 in total

1.  [A miniaturized method for some biochemical tests of bacteric identification (author's transl)].

Authors:  A Proietti; I Piacentini
Journal:  Quad Sclavo Diagn       Date:  1978-03

2.  Microfermentation series for identification of single colonies of Enterobacteriaceae.

Authors:  C N Huhtanen; J Naghski; E S Dellamonica
Journal:  Appl Microbiol       Date:  1972-10

3.  Semiautomatic microtechnique for serial dilution-antibiotic sensitivity testing in the clinical laboratory.

Authors:  J D MacLowry; H H Marsh
Journal:  J Lab Clin Med       Date:  1968-10

4.  Rapid procedure for the detection of acid and gas production by bacterial cultures.

Authors:  D Y Fung; R D Miller
Journal:  Appl Microbiol       Date:  1970-09

5.  Detailed methodology and implementation of a semiautomated serial dilution microtechnique for antimicrobial susceptibility testing.

Authors:  J D MacLowry; M J Jaqua; S T Selepak
Journal:  Appl Microbiol       Date:  1970-07

6.  Serial dilution antibiotic sensitivity testing with the microtitrator system.

Authors:  J H Marymont; R M Wentz
Journal:  Am J Clin Pathol       Date:  1966-05       Impact factor: 2.493

7.  A microdilution method for antibiotic susceptibility testing: an evaluation.

Authors:  T L Gavan; M A Town
Journal:  Am J Clin Pathol       Date:  1970-06       Impact factor: 2.493

8.  Reader error in determining minimal inhibitory concentrations with microdilution susceptibility test panels.

Authors:  A L Barry; L E Braun
Journal:  J Clin Microbiol       Date:  1981-01       Impact factor: 5.948

9.  Evaluation of the MICUR system for quantitative antimicrobial susceptibility testing: a multiphasic comparison with reference methods.

Authors:  R N Jones; A L Barry; J Bigelow; T L Gavan; C Thornsberry
Journal:  J Clin Microbiol       Date:  1982-07       Impact factor: 5.948

10.  Preliminary evaluation of the autoSCAN-3, an instrument for automated reading an interpretation of microdilution trays: identification of aerobic gram-negative bacilli.

Authors:  P D Ellner; D A Myers
Journal:  J Clin Microbiol       Date:  1981-09       Impact factor: 5.948

View more
  2 in total

1.  Evaluation of the MicroScan antimicrobial susceptibility system with the autoSCAN-4 automated reader.

Authors:  C N Baker; S A Stocker; D L Rhoden; C Thornsberry
Journal:  J Clin Microbiol       Date:  1986-01       Impact factor: 5.948

Review 2.  ACP Best Practice No 167: the laboratory diagnosis of urinary tract infection.

Authors:  J C Graham; A Galloway
Journal:  J Clin Pathol       Date:  2001-12       Impact factor: 3.411