An evaluation of the Oxylog as a portable device with which to measure oxygen consumption.

M A Ballal, I A Macdonald.   

Abstract

The Oxylog, a portable device for measuring oxygen consumption, was evaluated under standard, laboratory conditions and with exercising human subjects. The difference in oxygen partial pressure between room air and a series of test gases measured by the Oxylog showed good agreement with results obtained using a paramagnetic analyser and stable values were obtained for at least 6 h. The measurement of oxygen consumption by the Oxylog was assessed under simulated conditions, with an anaesthetic ventilator, and in exercising human subjects. With a simulated steady-state oxygen consumption there was an initial delay of 2 min before any oxygen consumption was recorded. Subsequent increases in simulated oxygen consumption were detected within one minute. The oxygen consumption of exercising human subjects measured with the Oxylog showed very good agreement with simultaneous measurements obtained using the Douglas bag technique. The application of an appropriate conversion factor allows the individual's energy expenditure to be estimated from the oxygen consumption: in this study a factor of 20.08 kJ per litre oxygen consumption gave the best agreement with the Douglas bag estimate.

Entities:  

Mesh:

Year:  1982        PMID: 7105638     DOI: 10.1088/0143-0815/3/1/005

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  7 in total

1.  Reliability of measurement of oxygen uptake by a portable telemetric system.

Authors:  Y Kawakami; D Nozaki; A Matsuo; T Fukunaga
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

2.  Volume calibration of various gasmeters using a modified Tissot spirometer.

Authors:  C Wenzel; K Golka; F Klimmer; J Rutenfranz; H G Wenzel
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

3.  A comparison of the effects of mixed static and dynamic work with mainly dynamic work in hot conditions.

Authors:  I P Randle; S J Legg
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1985

Review 4.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

5.  A comparison of the relation between oxygen uptake and heart rate during different styles of aerobic dance and a traditional step test in women.

Authors:  J M Bell; E J Bassey
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

6.  A comparative study on different methods for the determination of energy expenditure.

Authors:  C Wenzel; H G Wenzel; K Golka; M Rutenfranz; J Rutenfranz
Journal:  Int Arch Occup Environ Health       Date:  1990       Impact factor: 3.015

7.  Validity and Reliability of the New Portable Metabolic Analyzer PNOE.

Authors:  Yiannis E Tsekouras; Konstantinos D Tambalis; Stavros E Sarras; Athanasios K Antoniou; Peter Kokkinos; Labros S Sidossis
Journal:  Front Sports Act Living       Date:  2019-09-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.