Literature DB >> 2295517

A comparative study on different methods for the determination of energy expenditure.

C Wenzel1, H G Wenzel, K Golka, M Rutenfranz, J Rutenfranz.   

Abstract

In order to determine energy expenditure, the Douglas Bag technique (DB) and Kofranyi-Michaelis respirometers (KM) have been widely used under field conditions for several decades. Some years ago the Oxylog (OX) method was developed, measuring simultaneously the difference of partial oxygen pressure in inspired and expired air (PO2 diff.) by two polarographic oxygen sensors. In order to compare these three methods laboratory experiments (3 test subjects, 5 different bicycle ergometer work loads, 180 measurements per apparatus) were performed. Oxygen uptake (VO2) varied between about 0.9 to 3.0 l/min. The VO2 data obtained by the DB method, which were used as a reference, and those obtained by the KM method agreed fairly well. The recorded data of OX underestimated VO2 up to 21%, with the deviation increasing with work intensity. A sufficient accuracy of recorded VO2 was observed only up to moderate work intensity. OX data calculated from ventilation volume of inspired air per minute (VI) and PO2 diff., measured by OX, were always about 19% higher than those recorded by OX. This means that the calculated VO2 values of the OX corresponded fairly well with DB values at heavy work loads. The reason for the differences between recorded and calculated OX data is still unknown. Further research is urgently needed.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2295517     DOI: 10.1007/bf00397856

Source DB:  PubMed          Journal:  Int Arch Occup Environ Health        ISSN: 0340-0131            Impact factor:   3.015


  9 in total

1.  An investigation of the Muller-Franz calorimeter.

Authors:  H J MONTOYE; W D VAN HUSS; E P REINEKE; J COCKRELL
Journal:  Int Z Angew Physiol       Date:  1958

2.  The oxylog [proceedings].

Authors:  S J Humphrey; H S Wolff
Journal:  J Physiol       Date:  1977-05       Impact factor: 5.182

3.  [Experiences with a cardiorecorder system for continuous 24-hour registration of heart rate].

Authors:  J Rutenfranz; V Seliger; K L Andersen; J Ilmarinen; R Flöring; M Rutenfranz; F Klimmer
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1977-03-15

4.  Respiratory and circulatory response to added air flow resistance during exercise.

Authors:  L Hermansen; Z Vokac; P Lereim
Journal:  Ergonomics       Date:  1972-01       Impact factor: 2.778

5.  Energy expenditure studies in military populations using Kofranyi-Michaelis respirometers.

Authors:  C F Consolazio
Journal:  Am J Clin Nutr       Date:  1971-12       Impact factor: 7.045

6.  Comparison of three field methods for measuring oxygen consumption.

Authors:  V Louhevaara; J Ilmarinen; P Oja
Journal:  Ergonomics       Date:  1985-02       Impact factor: 2.778

7.  An evaluation of the Oxylog as a portable device with which to measure oxygen consumption.

Authors:  M A Ballal; I A Macdonald
Journal:  Clin Phys Physiol Meas       Date:  1982-02

8.  The 'Oxylog': an evaluation.

Authors:  M H Harrison; G A Brown; A J Belyavin
Journal:  Ergonomics       Date:  1982-09       Impact factor: 2.778

9.  Development of a telemetry system for measuring oxygen uptake during sports activities.

Authors:  Y Ikegami; S Hiruta; H Ikegami; M Miyamura
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1988
  9 in total
  1 in total

1.  The energy expenditure of stair climbing one step and two steps at a time: estimations from measures of heart rate.

Authors:  Lewis G Halsey; David A R Watkins; Brendan M Duggan
Journal:  PLoS One       Date:  2012-12-12       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.