Literature DB >> 2079056

Volume calibration of various gasmeters using a modified Tissot spirometer.

C Wenzel1, K Golka, F Klimmer, J Rutenfranz, H G Wenzel.   

Abstract

Various methods for determinating energy expenditure by indirect calorimetry are used in laboratory and field studies such as the Douglas bag method, often used in combination with a wet gasmeter, the respirometer of Kofranyi and Michaelis (KM) and the Oxylog (OX). To calibrate the volume measurements of these pieces of apparatus a modified Tissot spirometer was built, consisting of an outer casing filled with water, a core and a bell. It was equipped with a solid counterbalance and with an additional roller chain, partly freely suspended on the side of the counterbalance. This construction allowed compensation for the varying buoyancies of the bell. The lift of the bell was measured by means of a vernier scale. From calculations of the geometric volume a revolution counter was adapted to record the moved volume in litres. By means of this spirometer volumes up to 200 l can be used for calibration at various physiological flow rates. Calibration procedures for KM, wet gasmeters and OX were developed. For OX a small inaccuracy up to 2.0% was observed within the flow range from 20 to 70 l.min-1. The inaccuracy increased at higher flow rates. Under defined calibration conditions the modified Tissot spirometer enabled repeated calibrations of different types of gasmeters.

Entities:  

Mesh:

Year:  1990        PMID: 2079056     DOI: 10.1007/BF00236056

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  9 in total

1.  Determination of the total daily energy expenditure in man by indirect calorimetry: assessment of the accuracy of a modern technique.

Authors:  J V DURNIN; J M BROCKWAY
Journal:  Br J Nutr       Date:  1959       Impact factor: 3.718

2.  An investigation of the Muller-Franz calorimeter.

Authors:  H J MONTOYE; W D VAN HUSS; E P REINEKE; J COCKRELL
Journal:  Int Z Angew Physiol       Date:  1958

3.  [The measurement of energy consumption in occupational work with an improved respiratory-gasmeter].

Authors:  E A MULLER; H FRANZ
Journal:  Arbeitsphysiologie       Date:  1952

4.  The oxylog [proceedings].

Authors:  S J Humphrey; H S Wolff
Journal:  J Physiol       Date:  1977-05       Impact factor: 5.182

5.  Energy expenditure studies in military populations using Kofranyi-Michaelis respirometers.

Authors:  C F Consolazio
Journal:  Am J Clin Nutr       Date:  1971-12       Impact factor: 7.045

6.  Comparison of three field methods for measuring oxygen consumption.

Authors:  V Louhevaara; J Ilmarinen; P Oja
Journal:  Ergonomics       Date:  1985-02       Impact factor: 2.778

7.  An evaluation of the Oxylog as a portable device with which to measure oxygen consumption.

Authors:  M A Ballal; I A Macdonald
Journal:  Clin Phys Physiol Meas       Date:  1982-02

8.  The 'Oxylog': an evaluation.

Authors:  M H Harrison; G A Brown; A J Belyavin
Journal:  Ergonomics       Date:  1982-09       Impact factor: 2.778

9.  Development of a telemetry system for measuring oxygen uptake during sports activities.

Authors:  Y Ikegami; S Hiruta; H Ikegami; M Miyamura
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1988
  9 in total
  1 in total

1.  White matter integrity in physically fit older adults.

Authors:  B Y Tseng; T Gundapuneedi; M A Khan; R Diaz-Arrastia; B D Levine; H Lu; H Huang; R Zhang
Journal:  Neuroimage       Date:  2013-06-12       Impact factor: 6.556

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.