Literature DB >> 7096382

Temperature elevations in orthopaedic cutting operations.

W R Krause, D W Bradbury, J E Kelly, E M Lunceford.   

Abstract

Temperature measurements were made in bovine cortical bone using two cutting burst at 20,000 and 100,000 rpm and two reciprocating saw blades at 20,000 strokes per minute. A combination of feed rates and depths of cuts were investigated for the cutting burs. Cortical temperatures decreased as a result of increases in feed rate, but increased as the depth of cut increased. Temperature increase due to an increase in rotational speed was dependent upon the particular bur. The cutting forces were observed to increase with feed rate and depth of cut, but to decrease with increased rotational speed. The effect of saw design and irrigation had a significant effect on the cortical temperature. Without irrigation, the bone temperature exceeded temperatures reported to produce thermal necrosis. Clinical tests during total joint replacement indicated saw temperatures exceeding 200 degrees C when irrigation was not used.

Entities:  

Mesh:

Year:  1982        PMID: 7096382     DOI: 10.1016/0021-9290(82)90173-7

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  12 in total

1.  Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.

Authors:  R A Delgado-Ruiz; E Velasco Ortega; G E Romanos; S Gerhke; I Newen; J L Calvo-Guirado
Journal:  Clin Oral Investig       Date:  2017-04-22       Impact factor: 3.573

2.  [Machining of bone with rotary cutting burrs].

Authors:  A Fuchsberger
Journal:  Unfallchirurgie       Date:  1989-04

3.  [Damaging temperature during the machining of bone].

Authors:  A Fuchsberger
Journal:  Unfallchirurgie       Date:  1988-08

4.  Distraction osteogenesis using a longitudinal corticotomy.

Authors:  Ma'ad F Al-Saati; Robert A Magnussen; Sebastien Lustig; Rodolphe Testa; Gazal Al-Saati; Faisal Al-Saati
Journal:  Int Orthop       Date:  2011-10-28       Impact factor: 3.075

5.  Evaluation of bone regeneration using the rat critical size calvarial defect.

Authors:  Patrick P Spicer; James D Kretlow; Simon Young; John A Jansen; F Kurtis Kasper; Antonios G Mikos
Journal:  Nat Protoc       Date:  2012-09-27       Impact factor: 13.491

6.  New implant designs for fracture fixation in osteoporotic bone.

Authors:  J Goldhahn; J Seebeck; R Frei; B Frenz; I Antoniadis; E Schneider
Journal:  Osteoporos Int       Date:  2004-11-05       Impact factor: 4.507

7.  [Reamed intramedullary nailing].

Authors:  U Pfister
Journal:  Orthopade       Date:  2010-02       Impact factor: 1.087

8.  Heat-shock-induced cellular responses to temperature elevations occurring during orthopaedic cutting.

Authors:  E B Dolan; M G Haugh; D Tallon; C Casey; L M McNamara
Journal:  J R Soc Interface       Date:  2012-08-22       Impact factor: 4.118

9.  Analysis of factors determining thermal changes at osteotomy site in dental implant placement - An in-vitro study.

Authors:  Radhu Raj; V Manju; Vinod Kumar-Gopal; Manu Eswar
Journal:  J Clin Exp Dent       Date:  2021-03-01

Review 10.  Piezoelectric Bone Surgery: A Review of the Literature and Potential Applications in Veterinary Oromaxillofacial Surgery.

Authors:  Philippe Hennet
Journal:  Front Vet Sci       Date:  2015-05-05
View more