Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.

R A Delgado-Ruiz1, E Velasco Ortega2, G E Romanos3, S Gerhke4, I Newen5, J L Calvo-Guirado6.   

Abstract

AIMS: To evaluate the real-time bone temperature changes during the preparation of the implant bed with a single-drill protocol with different drill designs and different slow drilling speeds in artificial type IV bone.
MATERIALS AND METHODS: For this experimental in vitro study, 600 implant bed preparations were performed in 10 bovine bone disks using three test slow drilling speeds (50/150/300 rpm) and a control drilling speed (1200 rpm). The temperature at crestal and apical areas and time variations produced during drilling with three different drill designs with similar diameter and length but different geometry were recorded with real-life thermographic analysis. Statistical analysis was performed by two-way analysis of variance. Multiple comparisons of temperatures and time with the different drill designs and speeds were performed with the Tukey's test.
RESULTS: T Max values for the control drilling speed with all the drill designs (D1 + 1200; D2 + 1200; D3 + 1200) were higher compared to those for the controls for 11 ± 1.32 °C (p < 0.05). The comparison of T Max within the test groups showed that drilling at 50 rpm resulted in the lowest temperature increment (22.11 ± 0.8 °C) compared to the other slow drilling speeds of 150 (24.752 ± 1.1 °C) and 300 rpm (25.977 ± 1.2 °C) (p < 0.042). Temperature behavior at crestal and apical areas was similar being lower for slow drilling speeds compared to that for the control drilling speed. Slow drilling speeds required significantly more time to finish the preparation of the implant bed shown as follows: 50 rpm > 150 rpm > 300 rpm > control (p < 0.05).
CONCLUSIONS: A single-drill protocol with slow drilling speeds (50, 150, and 300 rpm) without irrigation in type IV bone increases the temperature at the coronal and apical levels but is below the critical threshold of 47 °C. The drill design in single-drill protocols using slow speeds (50, 150, and 300 rpm) does not have an influence on the thermal variations. The time to accomplish the implant bed preparation with a single-drill protocol in type IV bone is influenced by the drilling speed and not by the drill design. As the speed decreases, then more time is required.

Entities:  

Keywords:  Bone drilling; Single bur; Slow drilling speed; Thermal analysis

Mesh:

Year:  2017        PMID: 28434045     DOI: 10.1007/s00784-017-2119-x

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  31 in total

1.  Increase of temperature during osteotomy. In vitro and in vivo investigations.

Authors:  R Wächter; P Stoll
Journal:  Int J Oral Maxillofac Surg       Date:  1991-08       Impact factor: 2.789

2.  Effect of feed rate and drill speed on temperatures in equine cortical bone.

Authors:  A R Toews; J V Bailey; H G Townsend; S M Barber
Journal:  Am J Vet Res       Date:  1999-08       Impact factor: 1.156

3.  Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production.

Authors:  S Iyer; C Weiss; A Mehta
Journal:  Int J Prosthodont       Date:  1997 Sep-Oct       Impact factor: 1.681

4.  Influence of different parameters on bone heating and drilling time in implantology.

Authors:  Y Reingewirtz; S Szmukler-Moncler; B Senger
Journal:  Clin Oral Implants Res       Date:  1997-06       Impact factor: 5.977

5.  Effect of drill speed on bone temperature.

Authors:  M B Abouzgia; J M Symington
Journal:  Int J Oral Maxillofac Surg       Date:  1996-10       Impact factor: 2.789

6.  Effect of low speed drilling on osseointegration using simplified drilling procedures.

Authors:  A Sarendranath; R Khan; N Tovar; C Marin; D Yoo; J Redisch; R Jimbo; P G Coelho
Journal:  Br J Oral Maxillofac Surg       Date:  2015-04-25       Impact factor: 1.651

7.  The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber.

Authors:  R A Eriksson; T Albrektsson
Journal:  J Oral Maxillofac Surg       Date:  1984-11       Impact factor: 1.895

8.  Simplified drilling technique does not decrease dental implant osseointegration: a preliminary report.

Authors:  Ryo Jimbo; Gabriela Giro; Charles Marin; Rodrigo Granato; Marcelo Suzuki; Nick Tovar; Thomas Lilin; Malvin Janal; Paulo G Coelho
Journal:  J Periodontol       Date:  2012-12-05       Impact factor: 6.993

9.  Thermal evaluation by infrared measurement of implant site preparation between single and gradual drilling in artificial bone blocks of different densities.

Authors:  S C Möhlhenrich; M Abouridouane; N Heussen; F Hölzle; F Klocke; A Modabber
Journal:  Int J Oral Maxillofac Surg       Date:  2016-06-11       Impact factor: 2.789

10.  A novel drilling procedure and subsequent bone autograft preparation: a technical note.

Authors:  Eduardo Anitua; Carmen Carda; Isabel Andia
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Jan-Feb       Impact factor: 2.804

View more
  3 in total

Review 1.  Low-speed drilling without irrigation versus conventional drilling for dental implant osteotomy preparation: a systematic review.

Authors:  Juan Carlos Bernabeu-Mira; David Soto-Peñaloza; Miguel Peñarrocha-Diago; Fabio Camacho-Alonso; Rebeca Rivas-Ballester; David Peñarrocha-Oltra
Journal:  Clin Oral Investig       Date:  2021-04-24       Impact factor: 3.573

2.  Recommended Drilling Parameters of Tungsten Carbide Round Drills for the Most Optimal Bone Removals in Oral Surgery.

Authors:  József Szalma; Ole Klein; Bálint Viktor Lovász; Edina Lempel; Sára Jeges; Lajos Olasz
Journal:  Biomed Res Int       Date:  2018-11-19       Impact factor: 3.411

3.  Healing at sites prepared using different drilling protocols. An experimental study in the tibiae of sheep.

Authors:  Vittorio Favero; Shigeru Sakuma; Karol Alí Apaza Alccayhuaman; Guillermo Alejandro Benedetto; Franco Bengazi; Daniele Botticelli
Journal:  PLoS One       Date:  2018-08-29       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.