Literature DB >> 7086622

Noninvasive pulsed Doppler determination of cardiac output in neonates and children.

D C Alverson, M Eldridge, T Dillon, S M Yabek, W Berman.   

Abstract

Mean blood flow velocity (VAo) in the ascending aorta was measured noninvasively in 33 children, ages 3 days to 17 years, by pulsed Doppler technique at the time of cardiac catheterization. Measurements were made from a suprasternal approach with a portable, range-gated device. The ascending aortic diameter was determined echocardiographically and aortic cross sectional area calculated (A = pi d2/4 cm2). Aortic flow (QAo) was computed from Doppler recordings: QAo (ml/minute) = VAo (cm/second) X A (cm2) X 60 (second/minute). Values were compared with cardiac outputs determined according to the Fick principle, using measured oxygen consumption calculated oxygen capacity, and oxygen saturation. Subjects with aortic valve abnormalities or left ventricular outflow tract obstruction were excluded from study. Agreement between the two methods was excellent (linear regression r = 0.98, slope = 1.07, y-intercept = -4.5 ml, range 403 to 5.540 ml/minute). The Doppler technique is a quick, noninvasive, and accurate method of determining ascending aortic blood flow in neonates and children.

Entities:  

Mesh:

Year:  1982        PMID: 7086622     DOI: 10.1016/s0022-3476(82)80178-9

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  44 in total

Review 1.  Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature.

Authors:  Michelle S Chew; Jan Poelaert
Journal:  Intensive Care Med       Date:  2003-09-04       Impact factor: 17.440

2.  Acute effects of instillation of surfactant in severe respiratory distress syndrome.

Authors:  H L Halliday; F B McCord; B G McClure; M M Reid
Journal:  Arch Dis Child       Date:  1989-01       Impact factor: 3.791

Review 3.  Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

Authors:  Koichi Suehiro; Alexandre Joosten; Linda Suk-Ling Murphy; Olivier Desebbe; Brenton Alexander; Sang-Hyun Kim; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

4.  Haemodynamic features at presentation in persistent pulmonary hypertension of the newborn and outcome.

Authors:  J R Skinner; S Hunter; E N Hey
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-01       Impact factor: 5.747

5.  Acute physiological effects of packed red blood cell transfusion in preterm infants with different degrees of anaemia.

Authors:  Laura K Fredrickson; Edward F Bell; Gretchen A Cress; Karen J Johnson; M Bridget Zimmerman; Larry T Mahoney; John A Widness; Ronald G Strauss
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2010-11-20       Impact factor: 5.747

6.  Left and right ventricular myocardial performance index (Tei index) in very-low-birth-weight infants.

Authors:  Masanori Murase; Akihito Ishida; Takeshi Morisawa
Journal:  Pediatr Cardiol       Date:  2009-05-30       Impact factor: 1.655

7.  Cardiac output by Doppler echocardiography in the premature baboon: comparison with radiolabeled microspheres.

Authors:  J P Kinsella; W R Morrow; D R Gerstmann; A F Taylor; R A deLemos
Journal:  Pediatr Cardiol       Date:  1991-04       Impact factor: 1.655

8.  Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.

Authors:  I Hudson; A Houston; T Aitchison; B Holland; T Turner
Journal:  Arch Dis Child       Date:  1990-01       Impact factor: 3.791

9.  Determination of cardiac output by an angle and diameter independent dual beam Doppler technique in critically ill infants.

Authors:  C F Wippermann; D Schranz; R Huth; F Zepp; H Oelert; B K Jüngst
Journal:  Br Heart J       Date:  1992-02

10.  Cardiac abnormalities in end stage renal failure and anaemia.

Authors:  K P Morris; J R Skinner; C Wren; S Hunter; M G Coulthard
Journal:  Arch Dis Child       Date:  1993-05       Impact factor: 3.791

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.