Literature DB >> 2407197

Reproducibility of measurements of cardiac output in newborn infants by Doppler ultrasound.

I Hudson1, A Houston, T Aitchison, B Holland, T Turner.   

Abstract

Interobserver reproducibility in deriving cardiac output by measuring aortic blood flow velocity and diameter with imaging and Doppler ultrasound was investigated in 20 healthy infants born at full term. Aortic diameter was measured in three ways. Mean blood flow velocity was measured at three sites with both continuous wave and pulsed Doppler. Two observers carried out each study independently. Intraobserver reproducibility was investigated in 12 infants using the suprasternal site for measuring blood flow velocity. The most reproducible determination of cardiac output was found when the suprasternal site with continuous wave Doppler was used for measurement of blood flow velocity and M mode trailing edge to leading edge echocardiography was used for diameter. Normal mean (2 SD) cardiac output is 231 (77) ml/kg/min. Technical difficulties in measuring aortic diameter accurately limit direct comparison between infants.

Entities:  

Mesh:

Year:  1990        PMID: 2407197      PMCID: PMC1590175          DOI: 10.1136/adc.65.1_spec_no.15

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  13 in total

1.  In vitro comparison of six commercially available thermodilution cardiac output systems.

Authors:  D J Powner; J V Snyder
Journal:  Med Instrum       Date:  1978 Mar-Apr

2.  Pulsed Doppler determinations of cardiac output in neonates: normal standards for clinical use.

Authors:  F J Walther; B Siassi; N A Ramadan; A K Ananda; P Y Wu
Journal:  Pediatrics       Date:  1985-11       Impact factor: 7.124

3.  Serial measurements of thoracic impedance and cardiac output in healthy neonates after normal delivery and caesarean section.

Authors:  U Freyschuss; G Noack; R Zetterström
Journal:  Acta Paediatr Scand       Date:  1979-05

4.  Neonatal cardiac output measurement using pulsed Doppler ultrasound.

Authors:  D C Alverson
Journal:  Clin Perinatol       Date:  1985-02       Impact factor: 3.430

5.  Cardiac output in newborn infants with transient myocardial dysfunction.

Authors:  F J Walther; B Siassi; N A Ramadan; P Y Wu
Journal:  J Pediatr       Date:  1985-11       Impact factor: 4.406

6.  Cardiac output in the neonatal period using impedance cardiography.

Authors:  K Costeloe; J Stocks; S Godfrey
Journal:  Pediatr Res       Date:  1977-12       Impact factor: 3.756

7.  Noninvasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of the literature.

Authors:  R A Nishimura; M J Callahan; H V Schaff; D M Ilstrup; F A Miller; A J Tajik
Journal:  Mayo Clin Proc       Date:  1984-07       Impact factor: 7.616

8.  Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution.

Authors:  M Mellander; K G Sabel; K Caidahl; L Solymar; B Eriksson
Journal:  Pediatr Cardiol       Date:  1987       Impact factor: 1.655

9.  Noninvasive measurement of cardiac output in healthy preterm and term newborn infants.

Authors:  D C Alverson; M W Eldridge; J D Johnson; M Aldrich; P Angelus; W Berman
Journal:  Am J Perinatol       Date:  1984-01       Impact factor: 1.862

10.  Digital subtraction angiography in patients with transposition of the great arteries after surgical repair.

Authors:  K J Chung; J R Hesselink; H L Chernoff; M B Kreidberg; R J Cleveland
Journal:  J Am Coll Cardiol       Date:  1985-01       Impact factor: 24.094

View more
  19 in total

1.  Superior vena cava flow in newborn infants: a novel marker of systemic blood flow.

Authors:  M Kluckow; N Evans
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-05       Impact factor: 5.747

2.  Haematocrit and red blood cell transport in preterm infants: an observational study.

Authors:  P Pladys; A Beuchée; E Wodey; L Tison; P Bétrémieux
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2000-03       Impact factor: 5.747

Review 3.  Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature.

Authors:  Michelle S Chew; Jan Poelaert
Journal:  Intensive Care Med       Date:  2003-09-04       Impact factor: 17.440

4.  Postnatal changes in cardiac output and haemorrheology in normal neonates born at full term.

Authors:  V H Mandelbaum; D C Alverson; A Kirchgessner; O Linderkamp
Journal:  Arch Dis Child       Date:  1991-04       Impact factor: 3.791

5.  Sequential cardiac troponin T following delivery and its relationship with myocardial performance in neonates with respiratory distress syndrome.

Authors:  Simon J Clark; Paul Newland; C William Yoxall; Nimish V Subhedar
Journal:  Eur J Pediatr       Date:  2005-10-15       Impact factor: 3.183

6.  Haemodynamic features at presentation in persistent pulmonary hypertension of the newborn and outcome.

Authors:  J R Skinner; S Hunter; E N Hey
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-01       Impact factor: 5.747

7.  Acute physiological effects of packed red blood cell transfusion in preterm infants with different degrees of anaemia.

Authors:  Laura K Fredrickson; Edward F Bell; Gretchen A Cress; Karen J Johnson; M Bridget Zimmerman; Larry T Mahoney; John A Widness; Ronald G Strauss
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2010-11-20       Impact factor: 5.747

8.  Intraobserver variation in Doppler ultrasound assessment of pulmonary artery pressure.

Authors:  N V Subhedar; N J Shaw
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-07       Impact factor: 5.747

9.  Continuous central venous oxygen saturation (ScvO2) measurement using a fibre optic catheter in newborn infants.

Authors:  M A van der Hoeven; W J Maertzdorf; C E Blanco
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-05       Impact factor: 5.747

10.  Genesis of Still's murmurs: a controlled Doppler echocardiographic study.

Authors:  H M Gardiner; H S Joffe
Journal:  Br Heart J       Date:  1991-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.