Evaluation of the parallel conductor theory for measuring human limb blood flow by electrical admittance plethysmography.

H Shimazu, K Yamakoshi, T Togawa, M Fukuoka, H Ito.   

Abstract

Entities:  

Mesh:

Year:  1982        PMID: 7076264     DOI: 10.1109/TBME.1982.324957

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


× No keyword cloud information.
  12 in total

1.  Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries.

Authors:  H Shimazu; A Kawarada; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

2.  Impedance plethysmography for blood flow measurements in human limbs. Part 2. Influence of limb cross-sectional area.

Authors:  Y Yamamoto; T Yamamoto; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1992-09       Impact factor: 2.602

3.  Noninvasive measurement of arterial elasticity in various human limbs.

Authors:  A Kawarada; H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1988-11       Impact factor: 2.602

4.  Noninvasive measurement of pressure/volume characteristics in human limb veins by electrical admittance plethysmography.

Authors:  H Shimazu; M Fukuoka; S Hayashi; K Seki; H Ito; K Yamakoshi; T Togawa
Journal:  Med Biol Eng Comput       Date:  1985-01       Impact factor: 2.602

5.  Noninvasive measurement of beat-to-beat vascular viscoelastic properties in human fingers and forearms.

Authors:  H Shimazu; M Fukuoka; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1985-01       Impact factor: 2.602

6.  The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients.

Authors:  H H Woltjer; H J Bogaard; H I van der Spoel; P M de Vries
Journal:  Intensive Care Med       Date:  1996-08       Impact factor: 17.440

7.  Corrected formula for estimating peripheral blood flow by impedance plethysmography.

Authors:  G D Jindal; S N Nerurkar; S A Pednekar; J P Babu; A C Bhuta; A K Deshpande
Journal:  Med Biol Eng Comput       Date:  1994-11       Impact factor: 2.602

8.  Impedance plethysmography for the evaluation of pulse-wave velocity in limbs.

Authors:  F Risacher; J Jossinet; E T McAdams; J McLaughlin; Y Mann; M Schmitt; A Matias; R Jarry
Journal:  Med Biol Eng Comput       Date:  1993-05       Impact factor: 2.602

9.  Voltage clamp method for the use of electrical admittance plethysmography in human body segments.

Authors:  K Yamakoshi; M Nakagawara
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

10.  Errors in four-electrode impedance plethysmography.

Authors:  D K Swanson; J G Webster
Journal:  Med Biol Eng Comput       Date:  1983-11       Impact factor: 2.602