Literature DB >> 3974318

Noninvasive measurement of beat-to-beat vascular viscoelastic properties in human fingers and forearms.

H Shimazu, M Fukuoka, H Ito, K Yamakoshi.   

Abstract

Entities:  

Mesh:

Year:  1985        PMID: 3974318     DOI: 10.1007/bf02444026

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  11 in total

1.  Electrical impedance plethysmography; a physical and physiologic approach to peripheral vascular study.

Authors:  J NYBOER
Journal:  Circulation       Date:  1950-12       Impact factor: 29.690

2.  [The length of the standing wave in the brachial artery of man].

Authors:  A BLEICHERT; R LEZGUS; F MARTINI
Journal:  Z Biol       Date:  1952

3.  Transthoracic admittance plethysmograph for measuring cardiac output.

Authors:  H Ito; K I Yamakoshi; T Togawa
Journal:  J Appl Physiol       Date:  1976-03       Impact factor: 3.531

4.  Noninvasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique.

Authors:  K Yamakoshi; A Kamiya; H Shimazu; H Ito; T Togawa
Journal:  Med Biol Eng Comput       Date:  1983-09       Impact factor: 2.602

5.  Evaluation of the parallel conductor theory for measuring human limb blood flow by electrical admittance plethysmography.

Authors:  H Shimazu; K Yamakoshi; T Togawa; M Fukuoka; H Ito
Journal:  IEEE Trans Biomed Eng       Date:  1982-01       Impact factor: 4.538

6.  New oscillometric method for indirect measurement of systolic and mean arterial pressure in the human finger. Part 2: correlation study.

Authors:  K Yamakoshi; H Shimazu; M Shibata; A Kamiya
Journal:  Med Biol Eng Comput       Date:  1982-05       Impact factor: 2.602

7.  Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

8.  Noninvasive measurement of hematocrit by electrical admittance plethysmography technique.

Authors:  K I Yamakoshi; H Shimazu; T Togawa; M Fukuoka; H Ito
Journal:  IEEE Trans Biomed Eng       Date:  1980-03       Impact factor: 4.538

9.  Admittance plethysmography for accurate measurement of human limb blood flow.

Authors:  K I Yamakoshi; H Shimazu; T Togawa; H Ito
Journal:  Am J Physiol       Date:  1978-12

10.  Indirect measurement of instantaneous arterial blood pressure in the rat.

Authors:  K I Yamakoshi; H Shimazu; T Togawa
Journal:  Am J Physiol       Date:  1979-11
View more
  8 in total

1.  Mathematical modelling of non-invasive oscillometric finger mean blood pressure measurement by maximum oscillation criterion.

Authors:  R Raamat; J Talts; K Jagomägi; E Länsimies
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

2.  Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries.

Authors:  H Shimazu; A Kawarada; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

3.  Noninvasive measurement of arterial elasticity in various human limbs.

Authors:  A Kawarada; H Shimazu; H Ito; K Yamakoshi
Journal:  Med Biol Eng Comput       Date:  1988-11       Impact factor: 2.602

4.  Noninvasive automatic measurement of arterial elasticity in human fingers and rabbit forelegs using photoelectric plethysmography.

Authors:  A Kawarada; H Shimazu; K Yamakoshi; A Kamiya
Journal:  Med Biol Eng Comput       Date:  1986-11       Impact factor: 2.602

5.  Volume elastic modulus with exponential function of transmural pressure as a valid stiffness measure derived by photoplethysmographic volume-oscillometry in human finger and radial arteries: potential for arteriosclerosis screening.

Authors:  Takehiro Yamakoshi; Peter Rolfe; Akira Kamiya; Ken-Ichi Yamakoshi
Journal:  Med Biol Eng Comput       Date:  2021-07-15       Impact factor: 2.602

6.  Vibration plethysmography: a method for studying the visco-elastic properties of finger arteries.

Authors:  J Penaz; N Honzikova; P Jurak
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

7.  Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.

Authors:  S Takatani; C Davies; N Sakakibara; A Zurick; E Kraenzler; L R Golding; G P Noon; Y Nose; M E DeBakey
Journal:  J Clin Monit       Date:  1992-10

8.  Noninvasive measurement of elastic properties in human finger arteries: clinical data comparing blood pressure and funduscopic examination.

Authors:  K Seki
Journal:  Heart Vessels       Date:  1988       Impact factor: 2.037

  8 in total