Literature DB >> 704205

Evaluating indirect blood pressure measurement techniques: a comparison of three systems in infants and children.

R F Reder, I Dimich, M L Cohen, L Steinfeld.   

Abstract

The systemic arterial blood pressures obtained in infants and children utilizing three indirect measuring devices--Arteriosonde 1010. Infrasonde 3000, Pedisphyg system--were compared to each other and to intra-arterial pressure measured directly. The results indicate that Arteriosonde performs considerably better than Infrasonde; nevertheless, the Arteriosonde values are often only approximations of true systole and diastole. The Pedisphyg system yields accurate, reproducible values for systole; however, the system is not designed to determine diastolic blood pressure.

Entities:  

Mesh:

Year:  1978        PMID: 704205

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  9 in total

1.  Systolic arterial pressure determination by a new pulse monitor technique.

Authors:  D T Wong; G A Volgyesi; B Bissonnette
Journal:  Can J Anaesth       Date:  1992-07       Impact factor: 5.063

2.  Abstracts: annual meeting of the Canadian Anesthetists' Society. June 26-29, 1988, Halifax, Nova Scotia.

Authors: 
Journal:  Can J Anaesth       Date:  1988-05       Impact factor: 5.063

3.  Maternal methyldopa treatment and neonatal blood pressure.

Authors:  A Whitelaw
Journal:  Br Med J (Clin Res Ed)       Date:  1981-08-15

4.  Non-invasive oscillometric measurement of systolic, mean and diastolic blood pressure in infants with congenital heart defects after operation. A comparison with direct blood pressure measurements.

Authors:  V Pilossoff; J G Schöber; D Peters; K Bühlmeyer
Journal:  Eur J Pediatr       Date:  1985-11       Impact factor: 3.183

5.  Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger.

Authors:  N T Smith; K H Wesseling; B de Wit
Journal:  J Clin Monit       Date:  1985-01

6.  Systolic blood pressure in babies of less than 32 weeks gestation in the first year of life. Northern Neonatal Nursing Initiative.

Authors: 
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-01       Impact factor: 5.747

Review 7.  Principles and techniques of blood pressure measurement.

Authors:  Gbenga Ogedegbe; Thomas Pickering
Journal:  Cardiol Clin       Date:  2010-11       Impact factor: 2.213

8.  Blood pressure in infants children and adolescents.

Authors:  A J Moss
Journal:  West J Med       Date:  1981-04

9.  Transcranial Doppler sonography: nitrous oxide and cerebral blood flow velocity in children.

Authors:  J E Leon; B Bissonnette
Journal:  Can J Anaesth       Date:  1991-11       Impact factor: 5.063

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.