Literature DB >> 6994639

Evaluation of an enzyme immunoassay for serum gentamicin.

T D O'Leary, R M Ratcliff, T D Geary.   

Abstract

The EMIT (Enzyme Multiplied Immunoassay Technique) for serum gentamicin determination was evaluated by a standard procedure. The precision, accuracy, and specificity were assessed and proved satisfactory. Comparison with a bioassay was done, and results for patient samples showed a correlation coefficient of 0.95 between the two methods. Advantages of the enzyme immunoassay system were the provision of results within 15 min of receipt of blood in the laboratory, a requirement of minimal technical expertise, and an applicability to both large and small workloads. The EMIT proved during evaluation to be a practical alternative to current bioassays for the determination of serum gentamicin concentrations.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6994639      PMCID: PMC283874          DOI: 10.1128/AAC.17.5.776

Source DB:  PubMed          Journal:  Antimicrob Agents Chemother        ISSN: 0066-4804            Impact factor:   5.191


  11 in total

1.  Determining antibiotic levels in the blood.

Authors:  S C Edberg; A Chu
Journal:  Am J Med Technol       Date:  1975-03

2.  Inactivation of gentamicin by penicillins in patients with renal failure.

Authors:  F R Ervin; W E Bullock; C E Nuttall
Journal:  Antimicrob Agents Chemother       Date:  1976-06       Impact factor: 5.191

Review 3.  Determination of aminoglycoside antibiotics in biological fluids: a review.

Authors:  S K Maitra; T T Yoshikawa; L B Guze; M C Schotz
Journal:  Clin Chem       Date:  1979-08       Impact factor: 8.327

4.  A rapid chemical assay for gentamicin.

Authors:  D H Smith; B Van Otto; A L Smith
Journal:  N Engl J Med       Date:  1972-03-16       Impact factor: 91.245

5.  Letter: Quality control of gentamicin assays.

Authors:  D S Reeves
Journal:  Lancet       Date:  1974-09-14       Impact factor: 79.321

6.  "Homogeneous" enzyme immunoassay. A new immunochemical technique.

Authors:  K E Rubenstein; R S Schneider; E F Ullman
Journal:  Biochem Biophys Res Commun       Date:  1972-05-26       Impact factor: 3.575

7.  The acetyltransferase enzyme method for the assay of serum gentamicon concentrations and a comparison with other methods.

Authors:  J M Broughall; D S Reeves
Journal:  J Clin Pathol       Date:  1975-02       Impact factor: 3.411

8.  Polarisation fluoroimmunoassay of gentamicin.

Authors:  R A Watson; J Landon; E J Shaw; D S Smith
Journal:  Clin Chim Acta       Date:  1976-11-15       Impact factor: 3.786

9.  High-performance liquid-chromatographic assay of aminoglycoside antibiotics in serum.

Authors:  J P Anhalt; S D Brown
Journal:  Clin Chem       Date:  1978-11       Impact factor: 8.327

10.  Radioimmunoassay for measurement of gentamicin in blood.

Authors:  W A Mahon; J Ezer; T W Wilson
Journal:  Antimicrob Agents Chemother       Date:  1973-05       Impact factor: 5.191

View more
  14 in total

1.  Release of gentamicin from acrylic bone cement.

Authors:  L Bunetel; A Segui; M Cormier; E Percheron; F Langlais
Journal:  Clin Pharmacokinet       Date:  1989-10       Impact factor: 6.447

2.  Comparison of the Beckman Auto ICS and the Syva Autolab 6000 for determination of gentamicin levels in serum.

Authors:  R H Glew; R A Pavuk
Journal:  J Clin Microbiol       Date:  1985-01       Impact factor: 5.948

Review 3.  Drug interferences with plasma assays in therapeutic drug monitoring.

Authors:  S Yosselson-Superstine
Journal:  Clin Pharmacokinet       Date:  1984 Jan-Feb       Impact factor: 6.447

4.  Comparison of different tobramycin assays.

Authors:  E E Stobberingh; A W Houben; C P van Boven
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

5.  Homogeneous enzyme immunoassay for netilmicin.

Authors:  M Wenk; R Hemmann; F Follath
Journal:  Antimicrob Agents Chemother       Date:  1982-12       Impact factor: 5.191

6.  Comparison of a simplified liquid chromatographic assay of gentamicin in serum with enzyme immunoassay and bioassay.

Authors:  L Essers
Journal:  Eur J Clin Microbiol       Date:  1982-12       Impact factor: 3.267

7.  Comparison of an HPLC method with a RIA, EMIT and FIA method for the assay of serum gentamicin with extensive statistical evaluation.

Authors:  W Hospes; R J Boskma; J R Brouwers
Journal:  Pharm Weekbl Sci       Date:  1982-04-23

8.  Potential liabilities of gentamicin homogeneous enzyme immunoassay.

Authors:  L G Carlson; C J Delaney; J J Plorde
Journal:  Antimicrob Agents Chemother       Date:  1982-01       Impact factor: 5.191

9.  Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin.

Authors:  C J Delaney; K E Opheim; A L Smith; J J Plorde
Journal:  Antimicrob Agents Chemother       Date:  1982-01       Impact factor: 5.191

10.  Stability of gentamicin, tobramycin, and amikacin in combination with four beta-lactam antibiotics.

Authors:  R H Glew; R A Pavuk
Journal:  Antimicrob Agents Chemother       Date:  1983-10       Impact factor: 5.191

View more