Literature DB >> 6991590

Optical errors in scanning stage absorbance cytophotometry. II. Application of correction factors for residual distributional error, glare and diffraction error in practical cytophotometry.

W A Duijndam, P Van Duijn, S H Riddersma.   

Abstract

In a preceding article theoretical methods were derived for correcting the integrated absorbance values of microscopic objects determined with a scanning stage cytophotometer for the systematical erros due to residual distributional error, diffraction error, and glare error. For an experimental investigation of these results, the local apparant transmission at the center of an opaque particle was determined and this value used as a measure for the substage glare. By sufficient reduction of the size of the illuminated field, this substage glare could be kept below 1% in our scanning stage cytophotometer. The magnitude of the diffraction error was experimentally approached by comparing the values found for the integrated absorbance of the same amount of chromophore, dispersed over two different areas by crushing or centrifugation. After appropriate correction for the residual distributional error, the remaining difference was ascribed to the diffraction error, caused by diffraction at the edges of the object, and to the glare error, present all over the measured area. The local borderline corrections found necessary to obtain the best matching corrected integrated absorbance values were between 3 and 5%, in good agreement with the value derived theoretically. The importance of these corrections for the determination of the integrated absorbance of common biological objects is discussed.

Mesh:

Year:  1980        PMID: 6991590     DOI: 10.1177/28.5.6991590

Source DB:  PubMed          Journal:  J Histochem Cytochem        ISSN: 0022-1554            Impact factor:   2.479


  13 in total

Review 1.  A user's guide for avoiding errors in absorbance image cytometry: a review with original experimental observations.

Authors:  P Chieco; A Jonker; C Melchiorri; G Vanni; C J Van Noorden
Journal:  Histochem J       Date:  1994-01

Review 2.  Developments in photometric techniques in static and flow systems from 1960 to 1980: a review, including some personal observations.

Authors:  J James
Journal:  Histochem J       Date:  1983-02

3.  HISTOSCAN: computer program for cytophotometry in tissue sections and its application in the evaluation of nuclear atypia.

Authors:  K Bjelkenkrantz; O Stål; O Gröntoft; J Olofsson; A Herder; H Hellquist
Journal:  Histochemistry       Date:  1981-12

Review 4.  Trends in quantification in histochemistry and cytochemistry.

Authors:  D Glick
Journal:  Histochem J       Date:  1981-03

5.  Histochemical model studies of enzyme activity after thermal damage.

Authors:  E Prosperi; A K Raap; M van der Ploeg
Journal:  Histochemistry       Date:  1982

6.  Quantitative aspects of the cytochemical Feulgen-DNA procedure studied on model systems and cell nuclei.

Authors:  A C Van Prooijen-Knegt; C A Redi; M Van der Ploeg
Journal:  Histochemistry       Date:  1980

Review 7.  Errors in microdensitometry.

Authors:  D J Goldstein
Journal:  Histochem J       Date:  1981-03

8.  A fast and reliable system for microcomputerized DNA cytofluorometry in tumour pathology.

Authors:  K Bjelkenkrantz; O Stål; O Gröntoft
Journal:  Histochemistry       Date:  1983

9.  An evaluation of Feulgen-acriflavine-SO2 and Hoechst 33258 for DNA cytofluorometry in tumour pathology.

Authors:  K Bjelkenkrantz
Journal:  Histochemistry       Date:  1983

10.  Cytophotometric re-investigation of DNA content in Purkinje cells of the rat cerebellum.

Authors:  V Mares; M van der Ploeg
Journal:  Histochemistry       Date:  1980
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.