Literature DB >> 7035411

HISTOSCAN: computer program for cytophotometry in tissue sections and its application in the evaluation of nuclear atypia.

K Bjelkenkrantz, O Stål, O Gröntoft, J Olofsson, A Herder, H Hellquist.   

Abstract

The grading of nuclear atypia has a great and well recognized value when predicting the malignancy of neoplastic processes. Although the basic criteria for the grading are generally agreed upon, in the individual case, the final judgement is to some extent still a matter of subjectivity, which naturally impairs reproducibility. The present paper describes a method for quantification of variability of nuclear size and Feulgen-stainability. By plotting the mean optical density against the area value in a scatter-diagram, a cluster is obtained, the size of which reflects the degree of nuclear atypia. The measurements are performed in tissue sections using stage scanning cytophotometry. A computer program--HISTOSCAN--has been developed which enables measurements in highly cellular tissues. The system is also insensitive to the influence of light scattering, a factor of importance when measuring in tissue sections. The performance of the program is tested in both imprints and tissue sections.

Entities:  

Mesh:

Year:  1981        PMID: 7035411     DOI: 10.1007/bf00495649

Source DB:  PubMed          Journal:  Histochemistry        ISSN: 0301-5564


  10 in total

1.  The dependance of the absorbance of the final chromophore formed in the Feulgen-Schiff reaction on the pH of the medium.

Authors:  W A Duijndam; P van Duijn
Journal:  Histochemie       Date:  1973-06-29

2.  [Proportionality errors during Feulgen hydrolysis].

Authors:  N Böhm; E Sprenger; G Schlüter; W Sandritter
Journal:  Histochemie       Date:  1968

3.  Optical errors in scanning stage absorbance cytophotometry. II. Application of correction factors for residual distributional error, glare and diffraction error in practical cytophotometry.

Authors:  W A Duijndam; P Van Duijn; S H Riddersma
Journal:  J Histochem Cytochem       Date:  1980-05       Impact factor: 2.479

4.  Optical errors in scanning stage absorbance cytophotometry. I. Procedures for correcting apparent integrated absorbance values for distributional, glare, and diffraction errors.

Authors:  W A Duijndam; A W Smeulders; P Van Duijn; A C Verweij
Journal:  J Histochem Cytochem       Date:  1980-05       Impact factor: 2.479

5.  HIDACSYS: computer programs for interactive scanning cytophotometry.

Authors:  M Van der Ploeg; K Van den Broek; A W Smeulders; A M Vossepoel; P Van Duijn
Journal:  Histochemistry       Date:  1977-12-28

6.  Dual wavelength scanning cytophotometry (Bicoscan).

Authors:  M Van der Ploeg; K Van den Broek; J P Mitchell
Journal:  Histochemistry       Date:  1979-07

7.  The interaction of apurinic acid aldehyde groups with pararosaniline in the Feulgen-Schiff and related staining procedures.

Authors:  W A Duijndam; P van Duijn
Journal:  Histochemistry       Date:  1975-07-16

8.  Malignancy grading of epithelial bladder tumours. Reproducibility of grading and comparison between forceps biopsy, aspiration biopsy and exfoliative cytology.

Authors:  C Busch; A Engberg; B J Norlén; B Stenkvist
Journal:  Scand J Urol Nephrol       Date:  1977

9.  Cytophotometric re-investigation of DNA content in Purkinje cells of the rat cerebellum.

Authors:  V Mares; M van der Ploeg
Journal:  Histochemistry       Date:  1980

10.  Cytophotometric characterization of the WHO grades of transitional cell neoplasms.

Authors:  K Bjelkenkrantz; A Herder; O Gröntoft; O Stål
Journal:  Pathol Res Pract       Date:  1982-07       Impact factor: 3.250

  10 in total
  4 in total

1.  Laser He/Ne light exposure of red blood cells.

Authors:  L Wilander; I Rundquist; P A Oberg; S Odman
Journal:  Med Biol Eng Comput       Date:  1986-09       Impact factor: 2.602

2.  A fast and reliable system for microcomputerized DNA cytofluorometry in tumour pathology.

Authors:  K Bjelkenkrantz; O Stål; O Gröntoft
Journal:  Histochemistry       Date:  1983

3.  An evaluation of Feulgen-acriflavine-SO2 and Hoechst 33258 for DNA cytofluorometry in tumour pathology.

Authors:  K Bjelkenkrantz
Journal:  Histochemistry       Date:  1983

4.  Cytophotometric determination of nuclear size and DNA distribution in different hyperfunctioning thyroid lesions.

Authors:  K Bjelkenkrantz; B Risberg; S Eneström; O Stål
Journal:  Virchows Arch A Pathol Anat Histopathol       Date:  1982
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.