Literature DB >> 6981306

The unreliability of CT numbers as absolute values.

C Levi, J E Gray, E C McCullough, R R Hattery.   

Abstract

The use of CT numbers as absolute values was examined by scanning a standard phantom on five CT scanners under a variety of conditions simulating those encountered in routine body CT scanning. The results show that: (1) There are significant differences in absolute CT numbers between most scanners (only one scanner produced CT numbers that were equal to zero for water); (2) There are significant differences in absolute CT numbers between two scanners of the same manufacturer and model that were examined; (3) There is a significant difference in CT numbers in a single phantom scan, dependent on location in the scan, and the format of this variability is not constant from one scanner to another; and (4) There may be a significant difference in absolute CT numbers depending on various physical factors (e.g., kilovoltage, phantom orientation in scan aperture, and position of the phantom in the scan aperture). The findings suggest that there is a wide range of CT numbers observed for a given tissue type as a result of scanner performance alone, and that if absolute CT numbers are to be used for diagnosis the user must document that these machine-related variations are less than the differences thought to be significant.

Mesh:

Year:  1982        PMID: 6981306     DOI: 10.2214/ajr.139.3.443

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  38 in total

1.  Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms.

Authors:  Izuru Matsuda; Masaaki Akahane; Jiro Sato; Masaki Katsura; Shigeru Kiryu; Naoki Yoshioka; Akira Kunimatsu; Kenji Ino; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-02       Impact factor: 2.374

2.  The Effect of Quantitative Computed Tomography Acquisition Protocols on Bone Mineral Density Estimation.

Authors:  Hugo Giambini; Dan Dragomir-Daescu; Paul M Huddleston; Jon J Camp; Kai-Nan An; Ahmad Nassr
Journal:  J Biomech Eng       Date:  2015-11       Impact factor: 2.097

3.  Adaptive correction of the pseudo-enhancement of CT attenuation for fecal-tagging CT colonography.

Authors:  Janne Näppi; Hiroyuki Yoshida
Journal:  Med Image Anal       Date:  2008-01-26       Impact factor: 8.545

4.  Quantitative MDCT analysis of pulmonary solid nodules using three parameters.

Authors:  Naoki Kutuya; Yutaka Ozaki; Yoshihisa Kurosaki
Journal:  Radiat Med       Date:  2008-09-04

Review 5.  Genitourinary applications of dual-energy CT.

Authors:  Terri J Vrtiska; Naoki Takahashi; Joel G Fletcher; Robert P Hartman; Lifeng Yu; Akira Kawashima
Journal:  AJR Am J Roentgenol       Date:  2010-06       Impact factor: 3.959

6.  How to distinguish between bleeding and coagulated extradural hematomas on the plain CT scanning.

Authors:  O F Petersen; J O Espersen
Journal:  Neuroradiology       Date:  1984       Impact factor: 2.804

7.  Dynamic CT brain scanning in the haemodynamic evaluation of cerebral arterial occlusive disease.

Authors:  S M Davis; B M Tress; J L Hopper; A H Kaye; S C Rossiter
Journal:  Neuroradiology       Date:  1987       Impact factor: 2.804

Review 8.  Radiographically detectable calcium and atherosclerosis: the connection and its exploitation.

Authors:  R Detrano; S Molloi
Journal:  Int J Card Imaging       Date:  1992

9.  Prospective, multicenter study on value of computerized tomography (CT) in gallstone disease in predicting response to bile acid therapy.

Authors:  M L Petroni; R P Jazrawi; A Grundy; A Lanzini; M G Pigozzi; A Biasio; K W Heaton; J Virjee; T C Northfield
Journal:  Dig Dis Sci       Date:  1995-09       Impact factor: 3.199

10.  Improvement of parenchymal and vascular enhancement using saline flush and power injection for multiple-detector-row abdominal CT.

Authors:  Helmut Schoellnast; Manfred Tillich; Hannes A Deutschmann; Uwe Stessel; Michael J Deutschmann; Gottfried J Schaffler; Renate Schoellnast; Martin M Uggowitzer
Journal:  Eur Radiol       Date:  2003-10-18       Impact factor: 5.315

View more