Literature DB >> 22135112

Precision of the measurement of CT numbers: comparison of dual-energy CT spectral imaging with fast kVp switching and conventional CT with phantoms.

Izuru Matsuda1, Masaaki Akahane, Jiro Sato, Masaki Katsura, Shigeru Kiryu, Naoki Yoshioka, Akira Kunimatsu, Kenji Ino, Kuni Ohtomo.   

Abstract

PURPOSE: To compare dual-energy computed tomography (CT) spectral imaging and conventional CT imaging in terms of precision of the measurement of CT numbers in phantoms.
MATERIALS AND METHODS: A circular phantom (CP) and an elliptical phantom (EP) were used. Capsules filled with iodine contrast media solutions at various concentration levels were placed in the phantoms. Conventional CT was performed at a tube voltage of 120 kVp. Simulated monochromatic images at 65 keV were obtained by dual-energy CT spectral imaging. The CT number of each iodine capsule was measured. A linear regression model was used to evaluate linearity, while analysis of covariance was used to investigate the degree of variability according to phantom shape for each imaging method.
RESULTS: With conventional imaging, the slopes of the regression lines for CT numbers measured at the EP center and EP periphery were significantly lower than those measured for CP (P < 0.0001 for both EP center vs. CP and for EP periphery vs. CP). No significant difference in slope was found among phantom shapes in dual-energy spectral CT imaging.
CONCLUSION: Computed tomography numbers varied considerably depending on the phantom shape in conventional CT, whereas dual-energy CT provided consistent CT numbers regardless of the phantom shape.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22135112     DOI: 10.1007/s11604-011-0004-0

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  23 in total

1.  Multi-detector row CT attenuation measurements: assessment of intra- and interscanner variability with an anthropomorphic body CT phantom.

Authors:  Bernard A Birnbaum; Nicole Hindman; Julie Lee; James S Babb
Journal:  Radiology       Date:  2007-01       Impact factor: 11.105

2.  Renal cyst pseudoenhancement: influence of multidetector CT reconstruction algorithm and scanner type in phantom model.

Authors:  Bernard A Birnbaum; Nicole Hindman; Julie Lee; James S Babb
Journal:  Radiology       Date:  2007-09       Impact factor: 11.105

3.  Pseudoenhancement of simple renal cysts: a comparison of single and multidetector helical CT.

Authors:  Joan P Heneghan; Audrey L Spielmann; Douglas H Sheafor; Mark A Kliewer; David M DeLong; Rendon C Nelson
Journal:  J Comput Assist Tomogr       Date:  2002 Jan-Feb       Impact factor: 1.826

4.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

5.  The effects of scatter in x-ray computed tomography.

Authors:  P M Joseph; R D Spital
Journal:  Med Phys       Date:  1982 Jul-Aug       Impact factor: 4.071

6.  The unreliability of CT numbers as absolute values.

Authors:  C Levi; J E Gray; E C McCullough; R R Hattery
Journal:  AJR Am J Roentgenol       Date:  1982-09       Impact factor: 3.959

7.  Factors influencing quantitative CT measurements of solitary pulmonary nodules.

Authors:  E A Zerhouni; J F Spivey; R H Morgan; F P Leo; F P Stitik; S S Siegelman
Journal:  J Comput Assist Tomogr       Date:  1982-12       Impact factor: 1.826

8.  Adrenal nonhyperfunctioning adenoma and nonadenoma: CT attenuation value as discriminative index.

Authors:  H Miyake; H Takaki; S Matsumoto; S Yoshida; T Maeda; H Mori
Journal:  Abdom Imaging       Date:  1995 Nov-Dec

9.  Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol.

Authors:  C Thomas; O Patschan; D Ketelsen; I Tsiflikas; A Reimann; H Brodoefel; M Buchgeister; U Nagele; A Stenzl; C Claussen; A Kopp; M Heuschmid; H-P Schlemmer
Journal:  Eur Radiol       Date:  2009-02-10       Impact factor: 5.315

10.  Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience.

Authors:  Anno Graser; Thorsten R C Johnson; Markus Bader; Michael Staehler; Nicolas Haseke; Konstantin Nikolaou; Maximilian F Reiser; Christian G Stief; Christoph R Becker
Journal:  Invest Radiol       Date:  2008-02       Impact factor: 6.016

View more
  13 in total

1.  Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT.

Authors:  Yue Dong; Ai Jun Shi; Jian Lin Wu; Ru Xin Wang; Li Fei Sun; Ai Lian Liu; Yi Jun Liu
Journal:  Eur Spine J       Date:  2015-06-13       Impact factor: 3.134

2.  Preliminary study on the differentiation between parapelvic cyst and hydronephrosis with non-calculous using only pre-contrast dual-energy spectral CT scans.

Authors:  Dong Han; Guangming Ma; Lequn Wei; Chenglong Ren; Jieli Zhou; Chen Shen; Taiping He
Journal:  Br J Radiol       Date:  2017-03-10       Impact factor: 3.039

3.  Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system.

Authors:  Jessica L Nute; Megan C Jacobsen; Wolfgang Stefan; Wei Wei; Dianna D Cody
Journal:  Med Phys       Date:  2018-03-15       Impact factor: 4.071

4.  Spectral CT imaging of intranodular hemorrhage in cases with challenging benign thyroid nodules.

Authors:  Ming Li; Xiangpeng Zheng; Feng Gao; Li Xiao; Yanqing Hua
Journal:  Radiol Med       Date:  2015-11-27       Impact factor: 3.469

5.  Epidermal growth factor receptor mutations in lung adenocarcinoma: associations between dual-energy spectral CT measurements and histologic results.

Authors:  Guojin Zhang; Junlin Zhou; Yuntai Cao; Jing Zhang; Zhiyong Zhao; Wenjuan Zhang
Journal:  J Cancer Res Clin Oncol       Date:  2020-09-26       Impact factor: 4.553

6.  Identification of epidermal growth factor receptor mutations in pulmonary adenocarcinoma using dual-energy spectral computed tomography.

Authors:  Meng Li; Li Zhang; Wei Tang; Yu-Jing Jin; Lin-Lin Qi; Ning Wu
Journal:  Eur Radiol       Date:  2018-10-26       Impact factor: 5.315

7.  Quantitative features of dual-energy spectral computed tomography for solid lung adenocarcinoma with EGFR and KRAS mutations, and ALK rearrangement: a preliminary study.

Authors:  Meng Li; Li Zhang; Wei Tang; Pei-Qing Ma; Li-Na Zhou; Yu-Jing Jin; Lin-Lin Qi; Ning Wu
Journal:  Transl Lung Cancer Res       Date:  2019-08

8.  Rapid-kilovoltage-switching dual-energy computed tomography (CT) for differentiating spinal osteolytic metastases from spinal infections.

Authors:  Yuan Yuan; Ning Lang; Huishu Yuan
Journal:  Quant Imaging Med Surg       Date:  2021-02

9.  Ultrasonographic observation of the breast in early postmenopausal women during therapy with Cimicifuga foetida extract and sequential therapy with estrogen and progestin.

Authors:  Sharen Gaowa; Ai-Jun Sun; Ying Jiang; Fa-Wei He; Ting-Ping Zheng; Ya-Ping Wang
Journal:  Chin Med J (Engl)       Date:  2015-04-20       Impact factor: 2.628

10.  Computed Tomography Number Measurement Consistency Under Different Beam Hardening Conditions: Comparison Between Dual-Energy Spectral Computed Tomography and Conventional Computed Tomography Imaging in Phantom Experiment.

Authors:  Tian He; Xiaojun Qian; Renyou Zhai; Zongtao Yang
Journal:  J Comput Assist Tomogr       Date:  2015 Nov-Dec       Impact factor: 1.826

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.