Literature DB >> 6978896

Determination of object contour from projections for attenuation correction in cranial positron emission tomography.

M Bergström, J Litton, L Eriksson, C Bohm, G Blomqvist.   

Abstract

A contour-finding algorithm is described by which the object periphery is outlined in positron emission tomography (PET) scans. The positions of maximum slopes are determined in the projections. These positions are shown to correspond well to the borders of the activity region. By backprojecting these points in the projections into the image plane, the size and shape of the region of activity must be outlined. Cord lengths across this region are then determined for attenuation correction. The accuracy of the algorithm has been tested on 10 patients with both PET and computed tomography (CT) examinations. Points on the periphery of the skull, as determined with the contour-finding algorithm in PET, coincided with those determined by CT, with a standard deviation of 1.5 mm and a maximum deviation of 3.5 mm. In testing the influence of the skull bone on the PET values, it was found that ignoring the higher attenuation coefficient of bone, 5 mm thick, in the attenuation correction caused an error in the determination of activity of 11% peripherally and 6% centrally in the object. These errors could be reduced to less than 1% by increasing the assumed attenuating region by 4.5 mm.

Entities:  

Mesh:

Year:  1982        PMID: 6978896     DOI: 10.1097/00004728-198204000-00022

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  33 in total

1.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging.

Authors:  A F Chatziioannou; S R Cherry; Y Shao; R W Silverman; K Meadors; T H Farquhar; M Pedarsani; M E Phelps
Journal:  J Nucl Med       Date:  1999-07       Impact factor: 10.057

2.  A perfusion-metabolic mismatch in Sturge-Weber syndrome: a multimodality imaging study.

Authors:  Bálint Alkonyi; Yanwei Miao; Jianlin Wu; Zhaocheng Cai; Jiani Hu; Harry T Chugani; Csaba Juhász
Journal:  Brain Dev       Date:  2011-11-08       Impact factor: 1.961

3.  Attenuation compensation in cerebral 3D PET: effect of the attenuation map on absolute and relative quantitation.

Authors:  Habib Zaidi; Marie-Louise Montandon; Daniel O Slosman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-22       Impact factor: 9.236

4.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

5.  Regional perfusion, oxygen metabolism, blood volume and immunoglobulin G accumulation at focal sites of infection in rabbits.

Authors:  M Senda; A J Fishman; S Weise; N M Alpert; J A Correia; R H Rubin; H W Strauss
Journal:  Eur J Nucl Med       Date:  1992

6.  A hybrid method of attenuation correction for positron emission tomography brain studies.

Authors:  V Bettinardi; M C Gilardi; S Cargnel; G Rizzo; M Teräs; G Striano; F Fazio
Journal:  Eur J Nucl Med       Date:  1994-12

7.  Non-stationary spatial filtering and accelerated curve fitting for parametric imaging with dynamic PET.

Authors:  K Herholz
Journal:  Eur J Nucl Med       Date:  1988

Review 8.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26

9.  Nitrogen-13 ammonia cardiac positron emission tomography in mice: effects of clonidine-induced changes in cardiac work on myocardial perfusion.

Authors:  Masayuki Inubushi; Maria C Jordan; Kenneth P Roos; Robert S Ross; Arion F Chatziioannou; David B Stout; Magnus Dahlbom; Heinrich R Schelbert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-10       Impact factor: 9.236

10.  Interictal regional slow activity in temporal lobe epilepsy correlates with lateral temporal hypometabolism as imaged with 18FDG PET: neurophysiological and metabolic implications.

Authors:  M Koutroumanidis; C D Binnie; R D Elwes; C E Polkey; P Seed; G Alarcon; T Cox; S Barrington; P Marsden; M N Maisey; C P Panayiotopoulos
Journal:  J Neurol Neurosurg Psychiatry       Date:  1998-08       Impact factor: 10.154

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.