Literature DB >> 6875114

Reproducibility of left ventricular volumes by two-dimensional echocardiography.

E P Gordon, I Schnittger, P J Fitzgerald, P Williams, R L Popp.   

Abstract

Reproducibility may be as important as absolute accuracy in assessing the utility of an echocardiographic method of left ventricular volume estimation for epidemiologic or physiologic studies. The magnitude of differences between measurements in the same subjects from day to day must be defined before any quantitative technique can be used reliably to document "real" changes in heart volume over time. Two-dimensional echocardiograms were performed serveral days apart in 30 subjects, including 20 normal subjects and 10 patients with stable coronary heart disease. Analyses of light-pen tracings provided measurements of end-diastolic volume, endsystolic volume and derived ejection fraction on both days, and differences in individual subjects between days were quantitated. Beat to beat, interobserver and intraobserver variability also were assessed. Although group values changed little from day to day, individual volume changes were substantial in some cases. Confidence limits for individual measurements were derived from analyses of intrasubject variability and were as follows: end-diastolic volume +/- 15%, end-systolic volume +/- 25%, ejection fraction +/- 10%. Confidence limits in a larger group of subjects were narrower; in a group of 30 subjects, changes of greater than 2% in end-diastolic volume, 5% in end-systolic volume and 2% in ejection fraction most likely represent real change. Intraobserver variability was minimal, but interobserver and beat to beat variability were of sufficient magnitude to suggest that serial measurements on a given subject be made ideally by a single person and that several cycles be averaged for a given measurement.

Entities:  

Mesh:

Year:  1983        PMID: 6875114     DOI: 10.1016/s0735-1097(83)80278-2

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  34 in total

1.  Comparison between ECTb and QGS for assessment of left ventricular function from gated myocardial perfusion SPECT.

Authors:  Kenneth Nichols; Cesar A Santana; Russell Folks; Elizabeth Krawczynska; C David Cooke; Tracy L Faber; Steven R Bergmann; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2002 May-Jun       Impact factor: 5.952

Review 2.  Techniques for comprehensive two dimensional echocardiographic assessment of left ventricular systolic function.

Authors:  T H Marwick
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

3.  Assessment of left ventricular volume and function by integration of simplified 3D echocardiography, tissue harmonic imaging and automated extraction of endocardial borders.

Authors:  Donato Mele; Roberta Teoli; Corrado Cittanti; Giovanni Pasanisi; Gabriele Guardigli; Robert A Levine; Roberto Ferrari
Journal:  Int J Cardiovasc Imaging       Date:  2004-06       Impact factor: 2.357

4.  Clinical validation of the gated blood pool SPECT QBS processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography.

Authors:  Marcus Hacker; Xaver Hoyer; Sandra Kupzyk; Christian La Fougere; Johann Kois; Hans-Ulrich Stempfle; Reinhold Tiling; Klaus Hahn; Stefan Störk
Journal:  Int J Cardiovasc Imaging       Date:  2005-11-22       Impact factor: 2.357

5.  Is magnetic resonance imaging the 'reference standard' for cardiac functional assessment? Factors influencing measurement of left ventricular mass and volumes.

Authors:  H Steen; K Nasir; E Flynn; I El-Shehaby; S Lai; H A Katus; D Bluemcke; J A C Lima
Journal:  Clin Res Cardiol       Date:  2007-09-07       Impact factor: 5.460

6.  Echocardiographic measurement methods for left ventricular linear dimensions in children result in predictable variations in results.

Authors:  Shelby Kutty; David Russell; Ling Li; Rimsha Hasan; Qinghai Peng; Peter C Frommelt; David A Danford
Journal:  Int J Cardiovasc Imaging       Date:  2013-12-10       Impact factor: 2.357

Review 7.  New advances in quantitative echocardiography.

Authors:  Steve L Liao; Mario J Garcia
Journal:  J Nucl Cardiol       Date:  2008 Mar-Apr       Impact factor: 5.952

Review 8.  Myocardial perfusion imaging versus two-dimensional echocardiography: comparative value in the diagnosis of coronary artery disease.

Authors:  M S Verani
Journal:  J Nucl Cardiol       Date:  1994 Jul-Aug       Impact factor: 5.952

9.  Reproducibility of left ventricular size, shape and mass with echocardiography, magnetic resonance imaging and radionuclide angiography in patients with anterior wall infarction. A plea for core laboratories.

Authors:  L H Baur; J J Schipperheyn; E A van der Velde; E E van der Wall; J H Reiber; R J van der Geest; P R van Dijkman; J G Gerritsen; B L van Eck-Smit; P J Voogd; A V Bruschke
Journal:  Int J Card Imaging       Date:  1996-12

10.  Assessment of left ventricular volume and mass by cine magnetic resonance imaging in patients with anterior myocardial infarction intra-observer and inter-observer variability on contour detection.

Authors:  N A Matheijssen; L H Baur; J H Reiber; E A van der Velde; P R van Dijkman; R J van der Geest; A de Roos; E E van der Wall
Journal:  Int J Card Imaging       Date:  1996-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.