Literature DB >> 6841580

Collaborative evaluation of the microbial profile system for quantitative antimicrobial susceptibility testing.

E H Gerlach, R N Jones, A L Barry.   

Abstract

This three-center collaborative study was conducted to evaluate samples of the Microbial Profile System (MPS) antimicrobial microdilution panels [previously produced by Minnesota Mining & Manufacturing Co., (3M Co.), St. Paul, Minn. and currently produced by Flow Laboratories, Inc., Rockville, Md.). This was a three-phase study. In phase I, the inter- and intralaboratory agreement was determined by using strains with selected ranges of susceptibility. The MPS and reference microdilution minimum inhibitory concentrations were within acceptable variation, +/- 1 dilution for 97.7% for the MPS and 98.8% for the reference microdilution panels for the intralaboratory comparisons. The percentage of strains with minimum inhibitory concentrations in the acceptable range for the interlaboratory variation was 96.2% for the MPS and 96.0% for the reference microdilution panels. The phase II studies used strains with known resistance mechanisms. The percent agreement with these strains was: Enterobacteriaceae, 94.5%; nonenteric gram-negative rods, 95.4%; staphylococci, 92.3%; and streptococci, 96.6%. The overall agreement within acceptable limits was 94.7% with these strains. When testing 359 clinical isolates, the frequency of strains within the acceptable range of agreement between the two methods was 97.3%. The MPS panels gave results in each of the three study phases equivalent to those obtained with the reference microdilution panels.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6841580      PMCID: PMC272662          DOI: 10.1128/jcm.17.3.436-444.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  10 in total

1.  In-use evaluation of a prediluted quantitative antibiotic susceptibility test device.

Authors:  R C Tilton; H D Isenberg
Journal:  Antimicrob Agents Chemother       Date:  1977-10       Impact factor: 5.191

2.  Antibiotic sensitivity testing. Report of an international collaborative study.

Authors:  H M Ericsson; J C Sherris
Journal:  Acta Pathol Microbiol Scand B Microbiol Immunol       Date:  1971

3.  Semiautomatic microtechnique for serial dilution-antibiotic sensitivity testing in the clinical laboratory.

Authors:  J D MacLowry; H H Marsh
Journal:  J Lab Clin Med       Date:  1968-10

4.  A microdilution method for antibiotic susceptibility testing: an evaluation.

Authors:  T L Gavan; M A Town
Journal:  Am J Clin Pathol       Date:  1970-06       Impact factor: 2.493

5.  Evaluation of the performance parameters of a prediluted, quantitative antibiotic susceptibility test device.

Authors:  R C Tilton; H D Isenberg
Journal:  Antimicrob Agents Chemother       Date:  1977-02       Impact factor: 5.191

6.  Evaluation of the Sceptor microdilution antibiotic susceptibility testing system: a collaborative investigation.

Authors:  R N Jones; C Thornsberry; A L Barry; T L Gavan
Journal:  J Clin Microbiol       Date:  1981-01       Impact factor: 5.948

7.  Evaluation of the micro-media system for quantitative antimicrobial drug susceptibility testing: a collaborative study.

Authors:  A L Barry; R N Jones; T L Gavan
Journal:  Antimicrob Agents Chemother       Date:  1978-01       Impact factor: 5.191

8.  High-performance liquid-chromatographic assay of aminoglycoside antibiotics in serum.

Authors:  J P Anhalt; S D Brown
Journal:  Clin Chem       Date:  1978-11       Impact factor: 8.327

9.  Evaluation of the sensititre microdilution antibiotic susceptibility system against recent clinical isolates: three-laboratory collaborative study.

Authors:  R N Jones; T L Gavan; A L Barry
Journal:  J Clin Microbiol       Date:  1980-04       Impact factor: 5.948

10.  Evaluation of the Sensititre system for quantitative antimicrobial drug susceptibility testing: a collaborative study.

Authors:  T L Gavan; R N Jones; A L Barry
Journal:  Antimicrob Agents Chemother       Date:  1980-03       Impact factor: 5.191

  10 in total
  2 in total

1.  Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Authors:  J M Boyce; L S Lytle; D A Walsh
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

2.  Effect of the source of Mueller-Hinton agar and resistance frequency on the detection of methicillin-resistant Staphylococcus aureus.

Authors:  J A Hindler; C B Inderlied
Journal:  J Clin Microbiol       Date:  1985-02       Impact factor: 5.948

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.