Literature DB >> 848934

Evaluation of the performance parameters of a prediluted, quantitative antibiotic susceptibility test device.

R C Tilton, H D Isenberg.   

Abstract

A multiwelled plastic strip containing prediluted antibiotics was tested. Antibiotics available at the time of testing included ampicillin, penicillin, methicillin, erythromycin, clindamycin, tetracycline, and minocycline. The effects of inoculum size, inoculum volume, temperature, and time of incubation were determined. A limited clinical evaluation using laboratory strains of selected bacteria proved this product to be a rapid, economical, and reliable method for the determination of the minimal inhibitory concentration of antibiotics.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 848934      PMCID: PMC351967          DOI: 10.1128/AAC.11.2.271

Source DB:  PubMed          Journal:  Antimicrob Agents Chemother        ISSN: 0066-4804            Impact factor:   5.191


  5 in total

1.  Antibiotic sensitivity testing. Report of an international collaborative study.

Authors:  H M Ericsson; J C Sherris
Journal:  Acta Pathol Microbiol Scand B Microbiol Immunol       Date:  1971

2.  Semiautomatic microtechnique for serial dilution-antibiotic sensitivity testing in the clinical laboratory.

Authors:  J D MacLowry; H H Marsh
Journal:  J Lab Clin Med       Date:  1968-10

3.  Antibiotic susceptibility testing by a standardized single disk method.

Authors:  A W Bauer; W M Kirby; J C Sherris; M Turck
Journal:  Am J Clin Pathol       Date:  1966-04       Impact factor: 2.493

4.  A microdilution method for antibiotic susceptibility testing: an evaluation.

Authors:  T L Gavan; M A Town
Journal:  Am J Clin Pathol       Date:  1970-06       Impact factor: 2.493

5.  Microdilution antibiotic susceptibility test: examination of certain variables.

Authors:  R C Tilton; L Lieberman; E H Gerlach
Journal:  Appl Microbiol       Date:  1973-11
  5 in total
  7 in total

1.  Biographical feature: Henry D. Isenberg, Ph.D.

Authors:  Erik Munson
Journal:  J Clin Microbiol       Date:  2014-12-10       Impact factor: 5.948

2.  Evaluation of the MicroScan antimicrobial susceptibility system with the autoSCAN-4 automated reader.

Authors:  C N Baker; S A Stocker; D L Rhoden; C Thornsberry
Journal:  J Clin Microbiol       Date:  1986-01       Impact factor: 5.948

3.  In-use evaluation of a prediluted quantitative antibiotic susceptibility test device.

Authors:  R C Tilton; H D Isenberg
Journal:  Antimicrob Agents Chemother       Date:  1977-10       Impact factor: 5.191

4.  Evaluation of the Sceptor microdilution antibiotic susceptibility testing system: a collaborative investigation.

Authors:  R N Jones; C Thornsberry; A L Barry; T L Gavan
Journal:  J Clin Microbiol       Date:  1981-01       Impact factor: 5.948

5.  Collaborative evaluation of the microbial profile system for quantitative antimicrobial susceptibility testing.

Authors:  E H Gerlach; R N Jones; A L Barry
Journal:  J Clin Microbiol       Date:  1983-03       Impact factor: 5.948

6.  Evaluation of the sensititre microdilution antibiotic susceptibility system against recent clinical isolates: three-laboratory collaborative study.

Authors:  R N Jones; T L Gavan; A L Barry
Journal:  J Clin Microbiol       Date:  1980-04       Impact factor: 5.948

7.  Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Authors:  J M Boyce; L S Lytle; D A Walsh
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.