Literature DB >> 6826709

Rapid latex agglutination test for rubella antibody.

J L Sever, N R Tzan, I C Shekarchi, D L Madden.   

Abstract

The latex agglutination card test (Rubascan) for the detection of rubella antibody was compared with the standard hemagglutination inhibition and enzyme-linked immunosorbent assay tests. There was complete agreement with sera which had hemagglutination inhibition titers of >/=16. Sera with low levels of antibody which were positive in the enzyme-linked immunosorbent assay, however, gave negative latex agglutination results approximately 25% of the time (false negatives), whereas sera which were negative in the enzyme-linked immunosorbent assay gave false-positive results in about 3% of the cases. The use of capillary "finger stick" plasma instead of venous sera resulted in additional false-negative latex agglutination tests among patients with very low antibody titers. Because of the simplicity of the method, it should be possible to use this test in physicians' offices and in large immunization campaigns. Care should be taken to become completely familiar with the procedures and reading of the agglutination patterns. Control sera should always be used. Interpretation of results should take into consideration the rates of false-negative and false-positive results noted above. These rates apply to sera with little or no antibody. In particular, negative tests should be confirmed with more specific methods in critical cases, such as pregnant women exposed to rubella or women of childbearing age who are being considered for immunization. There was no problem with the latex agglutination findings for sera with higher titers. Since results are available in 8 min, physicians should be able to counsel their patients rapidly and immunize, if necessary, while the patient is still present.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6826709      PMCID: PMC272572          DOI: 10.1128/jcm.17.1.52-54.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  3 in total

1.  Rubella diagnostic tests: what is a significant result?

Authors:  J L Sever; C Cleghorn
Journal:  Postgrad Med       Date:  1982-03       Impact factor: 3.840

2.  Comparison of hemagglutination inhibition test and enzyme-linked immunosorbent assay for determining antibody to rubella virus.

Authors:  I C Shekarchi; J L Sever; N Tzan; A Ley; L C Ward; D Madden
Journal:  J Clin Microbiol       Date:  1981-05       Impact factor: 5.948

3.  Evaluation of commercially available diagnostic test kits for rubella.

Authors:  G A Castellano; D L Madden; G T Hazzard; C S Cleghorn; D V Vails; A C Ley; N R Tzan; J L Sever
Journal:  J Infect Dis       Date:  1981-04       Impact factor: 5.226

  3 in total
  7 in total

1.  Evaluation of a new latex test and a new enzyme immunoassay for determination of rubella immunity.

Authors:  A E Simor; R Chua; D E Low
Journal:  J Clin Microbiol       Date:  1988-08       Impact factor: 5.948

2.  Differences in antibody responses with rapid agglutination tests for the detection of rubella antibodies.

Authors:  M A Chernesky; D J DeLong; J B Mahony; S Castriciano
Journal:  J Clin Microbiol       Date:  1986-04       Impact factor: 5.948

3.  Latex agglutination test for rubella antibodies: report based on data from the College of American Pathologists surveys, 1983 to 1985.

Authors:  L P Skendzel; D C Edson
Journal:  J Clin Microbiol       Date:  1986-09       Impact factor: 5.948

4.  Evaluation of a latex agglutination test for screening antibodies to rubella virus.

Authors:  P León; F de Ory; C Domingo; J A López; J M Echevarría
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1988-04       Impact factor: 3.267

5.  Detection of rubella virus immunoglobulin G (IgG) and IgM antibodies in whole blood on Whatman paper: comparison with detection in sera.

Authors:  V Punnarugsa; V Mungmee
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

6.  Comparison of a simple latex agglutination test with hemolysis-in-gel, hemagglutination inhibition, and radioimmunoassay for detection of rubella virus antibodies.

Authors:  P Väänänen; V M Häivä; P Koskela; O Meurman
Journal:  J Clin Microbiol       Date:  1985-05       Impact factor: 5.948

7.  Evaluation of microparticle enzyme immunoassays for immunoglobulins G and M to rubella virus and Toxoplasma gondii on the Abbott IMx automated analyzer.

Authors:  L E Schaefer; J W Dyke; F D Meglio; P R Murray; W Crafts; A C Niles
Journal:  J Clin Microbiol       Date:  1989-11       Impact factor: 5.948

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.