Determinants of distortions in CO2 catheter sampling systems: a mathematical model.

R A Epstein, A M Reznik, M A Epstein.   

Abstract

A mathematical model was developed to predict the distortions in the measured expiratory CO2 concentration time profile caused by catheter sampling systems. Parameters considered included the expiratory flow and concentration profiles, the sample flow rate, the sample tube dimensions and the sample cell volume. Unless care is taken in choosing the parameters of a catheter sampling system, particularly in the presence of low expiratory flow rates and short expiratory times, the CO2 concentration profile may be severely distorted. In worst case situations end tidal CO2 plateaux may not be recognized or alternately artifactual plateaux may be produced. Sample flow rate and sample cell volume are the most important parameters while distortion within the sample tube itself is relatively less important.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6771855     DOI: 10.1016/0034-5687(80)90028-6

Source DB:  PubMed          Journal:  Respir Physiol        ISSN: 0034-5687


  7 in total

Review 1.  Non-invasive monitoring of carbon-dioxide in newborns and children.

Authors:  S Dutta
Journal:  Indian J Pediatr       Date:  1999 Jan-Feb       Impact factor: 1.967

2.  Accuracy of end-tidal PCO2 measurements using a sidestream capnometer in infants and children ventilated with the Sechrist infant ventilator.

Authors:  S C Hillier; J M Badgwell; M E McLeod; R E Creighton; J Lerman
Journal:  Can J Anaesth       Date:  1990-04       Impact factor: 5.063

3.  End-expiratory carbon dioxide measurement as an estimate of alveolar carbon dioxide tension.

Authors:  R A Epstein; M A Epstein
Journal:  J Clin Monit       Date:  1986-04

4.  Capnometry in infants should not be done at lower sampling flow rates.

Authors:  N Gravenstein
Journal:  J Clin Monit       Date:  1989-01

5.  Accuracy of end-tidal carbon dioxide tension analyzers.

Authors:  D B Raemer; I Calalang
Journal:  J Clin Monit       Date:  1991-04

6.  Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques.

Authors:  A L Balogh; F Petak; G H Fodor; J Tolnai; Z Csorba; B Babik
Journal:  Br J Anaesth       Date:  2016-07       Impact factor: 9.166

7.  The most proximal and accurate site for sampling end-tidal CO2 in infants.

Authors:  L Halpern; B Bissonnette
Journal:  Can J Anaesth       Date:  1994-10       Impact factor: 5.063

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.