The most proximal and accurate site for sampling end-tidal CO2 in infants.

L Halpern1, B Bissonnette.   

Abstract

The most proximal site to sample end-tidal CO2 with reasonable accuracy in infants during pulmonary ventilation using a Mapleson D circuit remains controversial. The utilisation of high fresh gas flow near the site of gas sampling dilutes the expired gas and causes an underestimation of end-tidal CO2. In this study a laboratory model was used to identify, qualitatively and quantitatively, the most proximal site in the Mapleson D circuit where the measurement of end-tidal CO2 is not influenced by mixing with fresh gas. A fresh gas flow rate of between 2 and 15 L.min-1 with a respiratory rate of 20-30.min-1 and a tidal volume of 30-100 ml.min-1 was evaluated. This experiment was divided into two parts. Firstly, an infant lung model was used to visualize the site of mixing between fresh gas and smoke-labelled exhaled gas. Secondly, fresh gas flow and expired gas flow were controlled and the end-tidal CO2 concentration was measured along the length of the anaesthetic circuit to identify the site of mixing of fresh gas and expired gas during steady-state conditions. Three expired gas flows were studied at six fresh gas flows. In all our studies, the rate of fresh gas flow and expired gas flow influenced the site of mixing and degree of dilution but no mixing was observed distal to the point at which the endotracheal tube connector narrows to the diameter of the endotracheal tube (P < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8001218     DOI: 10.1007/BF03010942

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  15 in total

1.  Accuracy of end-tidal PCO2 measurements using a sidestream capnometer in infants and children ventilated with the Sechrist infant ventilator.

Authors:  S C Hillier; J M Badgwell; M E McLeod; R E Creighton; J Lerman
Journal:  Can J Anaesth       Date:  1990-04       Impact factor: 5.063

2.  Lung function in infants and young children: functional residual capacity, tidal volume, and respiratory rats.

Authors:  L M Taussig; T R Harris; M D Lebowitz
Journal:  Am Rev Respir Dis       Date:  1977-08

3.  Is distal sampling of end-tidal CO2 necessary in small subjects?

Authors:  G F Rich; M P Sullivan; J M Adams
Journal:  Anesthesiology       Date:  1990-08       Impact factor: 7.892

4.  Error in sampling of exhaled gases.

Authors:  R F Kaplan; D A Paulus
Journal:  Anesth Analg       Date:  1983-10       Impact factor: 5.108

5.  Determinants of distortions in CO2 catheter sampling systems: a mathematical model.

Authors:  R A Epstein; A M Reznik; M A Epstein
Journal:  Respir Physiol       Date:  1980-07

6.  Factors influencing capnography in the Bain circuit.

Authors:  N Gravenstein; S Lampotang; J E Beneken
Journal:  J Clin Monit       Date:  1985-01

7.  Deadspace and the single breath test for carbon dioxide during anaesthesia and artificial ventilation. Effects of tidal volume and frequency of respiration.

Authors:  R Fletcher; B Jonson
Journal:  Br J Anaesth       Date:  1984-02       Impact factor: 9.166

8.  End-tidal PCO2 measurements sampled at the distal and proximal ends of the endotracheal tube in infants and children.

Authors:  J M Badgwell; M E McLeod; J Lerman; R E Creighton
Journal:  Anesth Analg       Date:  1987-10       Impact factor: 5.108

9.  Single breath end-tidal CO2 estimates of arterial PCO2 in infants and children.

Authors:  B Bissonnette; J Lerman
Journal:  Can J Anaesth       Date:  1989-03       Impact factor: 5.063

10.  Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects.

Authors:  R A Schieber; A Namnoum; A Sugden; A L Saville; R A Orr
Journal:  J Clin Monit       Date:  1985-07
View more
  1 in total

1.  The Use of Catheter Mount Will Result in More Reliable Carbon Dioxide Monitoring under Fluid Exposing Conditions.

Authors:  Yongil Cho; Wonhee Kim; Tae Ho Lim; Hyuk Joong Choi; Jaehoon Oh; Bossng Kang; Youjin Kim; In Young Kim
Journal:  Emerg Med Int       Date:  2019-07-01       Impact factor: 1.112

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.