Literature DB >> 6704271

Measurement of the rates of nitrous oxide uptake and nitrogen excretion in man.

P C Beatty, B Kay, T E Healy.   

Abstract

Using a completely closed anaesthetic circuit, nitrous oxide uptake and nitrogen excretion were measured simultaneously in patients undergoing nitrous oxide in oxygen anaesthesia for abdominal surgery. The results have been compared with standard models of uptake and excretion. Mean nitrous oxide uptake was measured and did not exceed 400 ml min-1 (normalized to 70-kg man) and was not less than 60 ml min-1 at 100 min after the start of nitrous oxide in oxygen anaesthesia. Nitrogen excretion did not exceed 100 ml min-1 and was measurable (8 ml min-1) at 100 min. The persistence of nitrogen excretion contrasts with other published data obtained with intact volunteers and this suggests that exposure at surgery of abdominal tissues, including fat, affects substantially the rates of excretion and uptake after 70 min.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6704271     DOI: 10.1093/bja/56.3.223

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  7 in total

1.  Closed anesthesia with nitrous oxide.

Authors:  S Li; Z Wang; B Zeng; J Liu
Journal:  J Tongji Med Univ       Date:  1996

2.  Development and in vitro validation of a device for measuring non-shunt cardiac output by nitrous oxide throughflow.

Authors:  G M Vartuli; R B Burfoot; G J B Robinson; P J Peyton; P A Junor
Journal:  Med Biol Eng Comput       Date:  2002-07       Impact factor: 2.602

3.  Static and dynamic accuracy required of gas concentration measuring instruments.

Authors:  P C Beatty
Journal:  Med Biol Eng Comput       Date:  1991-03       Impact factor: 2.602

4.  EVALUATION OF A NEW ANAESTHESIA MACHINE (IN LOW FLOW CONDITION).

Authors:  A K Bhargava; H K Mahajan; B K Gandhi; S Sharma
Journal:  Med J Armed Forces India       Date:  2017-06-26

5.  [Desflurane and isoflurane in minimal-flow anesthesia. Consumption and costs with forced fresh gas reduction].

Authors:  H Buchinger; S Kreuer; M Paxian; R Larsen; W Wilhelm
Journal:  Anaesthesist       Date:  2006-08       Impact factor: 1.041

6.  Influence of the reference gas of paramagnetic oxygen analyzers on nitrogen concentrations during closed-circuit anesthesia.

Authors:  J F Hendrickx; A A van Zundert; A M de Wolf
Journal:  J Clin Monit Comput       Date:  1998-08       Impact factor: 2.502

7.  Sampled gas need not be returned during low-flow anesthesia.

Authors:  J P Bengtson; J Bengtsson; A Bengtsson; O Stenqvist
Journal:  J Clin Monit       Date:  1993-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.