Static and dynamic accuracy required of gas concentration measuring instruments.

P C Beatty1.   

Abstract

The dynamic and static accuracy required of gas concentration measuring instruments for the measurement of physiological parameters is discussed. Static accuracy is examined using error sensitivity analysis of a range of physiological measurements requiring gas concentration information. From this an acceptable static accuracy of +/- 0.1 per cent volume/volume is established as an acceptable accuracy. Dynamic accuracy is examined using an idealised exhaled carbon dioxide curve. By considering the contribution of various features in the curve to the power spectrum of the curve a 'rule of thumb' for acceptable dynamic bandwidth of acceptable bandwidth = 4 (heart rate/60) + 5 Hz where heart rate is in beats min-1, is developed.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1906961     DOI: 10.1007/bf02447106

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  The measurement of gaseous exchange during nitrous oxide anaesthesia.

Authors:  J F NUNN; J C POULIOT
Journal:  Br J Anaesth       Date:  1962-11       Impact factor: 9.166

2.  Cardiac oscillations in expired gas tensions, and regional pulmonary blood flow.

Authors:  K T FOWLER; J READ
Journal:  J Appl Physiol       Date:  1961-09       Impact factor: 3.531

3.  Pulmonary capillary blood volume, flow and diffusing capacity during exercise.

Authors:  R L JOHNSON; W S SPICER; J M BISHOP; R E FORSTER
Journal:  J Appl Physiol       Date:  1960-09       Impact factor: 3.531

4.  Pulmonary capillary blood flow in man.

Authors:  G D LEE; A B DUBOIS
Journal:  J Clin Invest       Date:  1955-09       Impact factor: 14.808

5.  The measurement of effective pulmonary blood flow in the newborn infant using a mass spectrometer.

Authors:  E K Cotton
Journal:  Crit Care Med       Date:  1976 Sep-Oct       Impact factor: 7.598

6.  The measurement of metabolic gas exchange and minute volume by mass spectrometry alone.

Authors:  N J Davies; D M Denison
Journal:  Respir Physiol       Date:  1979-02

7.  The Spectralab-M quadrupole medical mass spectrometer.

Authors:  P C Beatty
Journal:  J Med Eng Technol       Date:  1988 Nov-Dec

8.  Measurement of oxygen uptake: a method for use during nitrous oxide in oxygen anaesthesia.

Authors:  A T Cohen; P C Beatty; B Kay; T E Healy
Journal:  Eur J Anaesthesiol       Date:  1984-03       Impact factor: 4.330

9.  Blood-gas tension measurement in anaesthesia by bubble equilibration and mass spectrometry.

Authors:  W W Mapleson; B A Willis; B Williams
Journal:  Br J Anaesth       Date:  1980-11       Impact factor: 9.166

10.  Measurement of the rates of nitrous oxide uptake and nitrogen excretion in man.

Authors:  P C Beatty; B Kay; T E Healy
Journal:  Br J Anaesth       Date:  1984-03       Impact factor: 9.166

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.