Literature DB >> 6702751

Assessment of "Average of Normals" quality control procedures and guidelines for implementation.

G S Cembrowski, E P Chandler, J O Westgard.   

Abstract

The capabilities of "Average of Normals" control procedures have been assessed by determining power functions, graphs of the probability of error detection versus the size of analytic error. The power functions indicate that the most important determinants of statistical power are the ratio of the standard deviation of the patient population (Sp) to the analytic standard deviation (Sa), Sp/Sa; the number of data points averaged (N); the control limits (probability for false rejection); truncation limits for selecting the population; and the magnitude of the population lying outside the truncation limits. General guidelines for the implementation of "Average of Normals" are provided, along with a nomogram for the selection of N as a function of Sp/Sa and the probability of error detection. Optimal performance of these procedures may require simulation studies on a per analyte basis.

Entities:  

Mesh:

Year:  1984        PMID: 6702751     DOI: 10.1093/ajcp/81.4.492

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  7 in total

1.  Increases in whole blood glucose measurements using optically based self-monitoring of blood glucose analyzers due to extreme Canadian winters.

Authors:  George C Cembrowski; Barbara Smith; Ellen M O'Malley
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

2.  CUSUM-Logistic Regression analysis for the rapid detection of errors in clinical laboratory test results.

Authors:  Maureen L Sampson; Verena Gounden; Hendrik E van Deventer; Alan T Remaley
Journal:  Clin Biochem       Date:  2015-10-30       Impact factor: 3.281

3.  Missed detection of significant positive and negative shifts in gentamicin assay: implications for routine laboratory quality practices.

Authors:  Gus Koerbin; Jiakai Liu; Alex Eigenstetter; Chin Hon Tan; Tony Badrick; Tze Ping Loh
Journal:  Biochem Med (Zagreb)       Date:  2017-11-24       Impact factor: 2.313

4.  Optimization and validation of patient-based real-time quality control procedure using moving average and average of normals with multi-rules for TT3, TT4, FT3, FT3, and TSH on three analyzers.

Authors:  Chao Song; Jun Zhou; Jun Xia; Deli Ye; Qian Chen; Weixing Li
Journal:  J Clin Lab Anal       Date:  2020-05-03       Impact factor: 2.352

5.  A study of the moving rate of positive results for use in a patient-based real-time quality control program on a procalcitonin point-of-care testing analyzer.

Authors:  Yili He; Daqing Gu; Xiangzhi Kong; Zhiqiang Feng; Weishang Lin; Yunfeng Cai
Journal:  J Clin Lab Anal       Date:  2022-03-07       Impact factor: 2.352

6.  Assessment of patient based real-time quality control on comparative assays for common clinical analytes.

Authors:  Yide Lu; Fan Yang; Dongmei Wen; Kaifeng Shi; Zhichao Gu; Qiuya Lu; Xuefeng Wang; Danfeng Dong
Journal:  J Clin Lab Anal       Date:  2022-08-10       Impact factor: 3.124

7.  Optimizing moving average control procedures for small-volume laboratories: can it be done?

Authors:  Vera Lukić; Svetlana Ignjatović
Journal:  Biochem Med (Zagreb)       Date:  2019-10-15       Impact factor: 2.313

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.