Literature DB >> 6691118

Digital image processing: effect on detectability of simulated low-contrast radiographic patterns.

M Ishida, K Doi, L N Loo, C E Metz, J L Lehr.   

Abstract

Detection studies of simulated low-contrast radiographic patterns were performed with a high-quality digital image processing system. The original images, prepared with conventional screen-film systems, were processed digitally to enhance contrast by a "windowing" technique. The detectability of simulated patterns was quantified in terms of the results of observer performance experiments by using the multiple-alternative forced-choice method. The processed images demonstrated a significant increase in observer detection performance over that for the original images. These results are related to the displayed and perceived signal-to-noise ratios derived from signal detection theory. The improvement in detectability is ascribed to a reduction in the relative magnitude of the human observer's "internal" noise after image processing. The measured dependence of threshold signal contrast on object size and noise level is accounted for by a statistical decision theory model that includes internal noise.

Entities:  

Mesh:

Year:  1984        PMID: 6691118     DOI: 10.1148/radiology.150.2.6691118

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Fundamental properties of medical image perception.

Authors:  S M Pizer; B M ter Haar Romeny
Journal:  J Digit Imaging       Date:  1991-02       Impact factor: 4.056

2.  [A comparative study of the possibility of reducing the dosage in lateral teleradiographs].

Authors:  T Ruppenthal; B Fricke; H G Sergl; G Doll
Journal:  Fortschr Kieferorthop       Date:  1992-02

3.  Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose.

Authors:  Chao-Jen Lai; Chris C Shaw; Lingyun Chen; Mustafa C Altunbas; Xinming Liu; Tao Han; Tianpeng Wang; Wei T Yang; Gary J Whitman; Shu-Ju Tu
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

Review 4.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

5.  Comparison of a PACS workstation with conventional film for interpretation of neonatal examinations: a paired comparison study.

Authors:  E A Franken; W L Smith; K S Berbaum; S C Kao; Y Sato
Journal:  Pediatr Radiol       Date:  1991

6.  Correlation between human detection accuracy and observer model-based image quality metrics in computed tomography.

Authors:  Justin Solomon; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2016-09-22

7.  New computed radiography using scanning laser stimulated luminescence.

Authors:  H Kato; J Miyahara; M Takano
Journal:  Neurosurg Rev       Date:  1985       Impact factor: 3.042

8.  Development of a digital duplication system for portable chest radiographs.

Authors:  K R Hoffmann; K Doi; H MacMahon; M L Giger; R M Nishikawa; X W Xu; L Yao; A Kano; M Carlin
Journal:  J Digit Imaging       Date:  1994-08       Impact factor: 4.056

9.  CT iterative reconstruction algorithms: a task-based image quality assessment.

Authors:  J Greffier; J Frandon; A Larbi; J P Beregi; F Pereira
Journal:  Eur Radiol       Date:  2019-07-29       Impact factor: 5.315

10.  Statistical model based iterative reconstruction in clinical CT systems. Part III. Task-based kV/mAs optimization for radiation dose reduction.

Authors:  Ke Li; Daniel Gomez-Cardona; Jiang Hsieh; Meghan G Lubner; Perry J Pickhardt; Guang-Hong Chen
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.