Literature DB >> 7948174

Development of a digital duplication system for portable chest radiographs.

K R Hoffmann1, K Doi, H MacMahon, M L Giger, R M Nishikawa, X W Xu, L Yao, A Kano, M Carlin.   

Abstract

To provide high-quality duplicate chest images for the intensive care units, we have developed a digital duplication system in which film digitization is performed in conjunction with nonlinear density correction, contrast adjustment, and unsharp mask filtering. This system provides consistent image densities over a wide exposure range and enhancement of structures in the mediastinum and upper abdominal areas, improving visibility of catheters and tubes. The image quality is often superior to that of the original radiograph and is more consistent from day to day. Repeat rates for portable chest radiographs have been reduced by more than a factor of two since implementation of digitization in December 1991, and the number of repeat examinations caused by exposure errors have been substantially reduced.

Mesh:

Year:  1994        PMID: 7948174     DOI: 10.1007/bf03168508

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  6 in total

Review 1.  Transfer function analysis of radiographic imaging systems.

Authors:  C E Metz; K Doi
Journal:  Phys Med Biol       Date:  1979-11       Impact factor: 3.609

2.  Development of a high quality film duplication system using a laser digitizer: comparison with computed radiography.

Authors:  H Yoshimura; X W Xu; K Doi; H MacMahon; K R Hoffmann; M L Giger; S M Montner
Journal:  Med Phys       Date:  1993 Jan-Feb       Impact factor: 4.071

3.  Portable chest imaging: comparison of storage phosphor digital, asymmetric screen-film, and conventional screen-film systems.

Authors:  L T Niklason; H P Chan; P N Cascade; C L Chang; P W Chee; J F Mathews
Journal:  Radiology       Date:  1993-02       Impact factor: 11.105

4.  Clinical experience with an advanced laser digitizer for cost-effective digital radiography.

Authors:  H MacMahon; X W Xu; K R Hoffmann; M L Giger; H Yoshimura; K Doi; M Carlin; A Kano; L Yao; K Abe
Journal:  Radiographics       Date:  1993-05       Impact factor: 5.333

5.  Evaluation of an enhanced digital film-duplication system by receiver operating characteristic analysis.

Authors:  K R Hoffmann; H MacMahon; K Doi; C E Metz; L Yao; K Abe
Journal:  Invest Radiol       Date:  1993-12       Impact factor: 6.016

6.  Digital image processing: effect on detectability of simulated low-contrast radiographic patterns.

Authors:  M Ishida; K Doi; L N Loo; C E Metz; J L Lehr
Journal:  Radiology       Date:  1984-02       Impact factor: 11.105

  6 in total
  1 in total

1.  Support line and tube visibility in chest examinations using computed radiography.

Authors:  W Huda; C J Belden; L A Webb; C K Palmer
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.